Activity ID Activity Name WBS Status Start Finish Dur (d) Rem (d) % Comp Float (d)
RPL10.WP4.025320 RPL10.Conn NS3.CFD1.02<>01 Install Simplex Jumper at Z- End (SC<>LC) [PON] Install Simplex Jumper [PON] Not Started 12/15/26 12/15/26 1.2 1.2
0%
140.0
RPL10.WP4.031900 RPL10.Conn NS3.CFD6.48<>21-25 Prefab Duplex Jumper (LC<>LC) [RSW<>FSW] Prefab Not Started 12/15/26 12/18/26 5.0 5.0
0%
55.0
RPL10.WP4.05400 RPL10.Conn NS3.CFD3.23 Pull Duplex Jumper (LC<>LC) [MA<>JXSW] Pull Duplex Jumper [MA<>JXSW] Not Started 12/15/26 12/17/26 3.8 3.8
0%
133.8
RPL10.WP4.07880 RPL10.Conn NS4.CFD5.35 Pull Duplex Jumper (LC<>LC) [MA<>JXSW] Pull Duplex Jumper [MA<>JXSW] Not Started 12/15/26 12/17/26 3.8 3.8
0%
106.2
RPL10.WP4.09920 RPL10.Conn NS2.CFD1.46<>46 Pull/Install Trunk (384F) [MA<>EB] [MA<>EB] Not Started 12/15/26 12/16/26 2.5 2.5
0%
-18.8
RPL10.WP4.NS3.02760 RPL10.Conn NS3.CFD2 - Install ORv3 OFE - Passive In-row Racks, Racks (ORv3Ns, MCRs) & PON Not Started 12/15/26 12/23/26 8.8 8.8
0%
45.0
RPL10.WP4.NS3.02780 RPL10.Conn NS3.CFD2 - Deliver & Assemble - PON OFE - Passive In-row Racks, Racks (ORv3Ns, MCRs) & PON Not Started 12/15/26 12/23/26 8.8 8.8
0%
65.0
GCD.RPL10.6085 [RPL10] TC Ready: Production Cabling Pathways Complete [NS3 Rows 33-40] TC Ready: Production Cabling - NS3 Not Started 12/16/26 12/16/26 0.0 0.0
0%
43.8
RPL10.ORV3.010440 OFE - Delivery ROJ: ORv3 for CFD NS3.4 (ROJ 12.24.26) (RVCD 01.20.27) NS3 Not Started 12/16/26 01/07/27 18.8 18.8
0%
65.0
RPL10.PR.PR.01360 RPL10.PR NS1.PZ3 (Rows 01 - 16) - Remaining FENW Provisioning with NS1.PZ2 (Rows 17 - 32) FENW Not Started 12/16/26 12/22/26 6.2 6.2
0%
145.0
RPL10.PR12.01000 RPL10.Conn PR.Optical NWS1.1 and NWS2.1 - Provisioning (MA) NS-1/2 - Activation, Undraining Not Started 12/16/26 12/30/26 12.5 12.5
0%
665.0
RPL10.W3B.FE.011271 RPL10.Conn EF1B<>NS4.CFD5 (P2-3) Pull Fiber Trunk (384F) [EF<>SSW] EF1B<>NS4.5 (P2-3) [EF<>SSW] Not Started 12/16/26 12/17/26 2.5 2.5
0%
83.8
RPL10.W3B.FE.011531 RPL10.Conn EF2F<>NS3.CFD4 (P1-4) Pull Fiber Trunk (288F) [EF<>JXSW] EF2F<>NS3.4 (P1-4) [EF<>JXSW] Not Started 12/16/26 12/18/26 3.8 3.8
0%
28.8
RPL10.WP3B.FE.08500 RPL10.Conn EF2F<>NS3.CFD4 (P1-4) Pull/Install/Test - WBS Summary* EF2F<>NS3.4 (P1-4) [EF<>JXSW] Not Started 12/16/26 02/01/27 38.8 38.8
0%
7.5
RPL10.WP3B.FE.09520 RPL10.Conn EF1B<>NS4.CFD5 (P2-3) Pull/Install/Test - WBS Summary* EF1B<>NS4.5 (P2-3) [EF<>SSW] Not Started 12/16/26 02/12/27 50.0 50.0
0%
45.0
RPL10.WP4.015820 RPL10.Conn NS4.CFD6.41<>41 Pull & Install Simplex Jumper at A- End (SC<>LC) [PON] Pull Simplex Jumper [PON] Not Started 12/16/26 12/18/26 3.8 3.8
0%
116.2
RPL10.WP4.015860 RPL10.Conn NS4.CFD6.43<>43 Pull & Install Simplex Jumper at A- End (SC<>LC) [PON] Pull Simplex Jumper [PON] Not Started 12/16/26 12/18/26 3.8 3.8
0%
116.2
RPL10.WP4.017820 RPL10.Conn NS1.CFD1.48<>46-49 Install (A-End/Passive) Duplex Jumper (LC<>LC) [RSW<>FSW] Install (A-End/Passive) Duplex Jumper [RSW<>FSW] Not Started 12/16/26 12/17/26 2.5 2.5
0%
18.8
RPL10.WP4.019880 RPL10.Conn NS3.CFD1.48<>46-49 Install (A-End/Passive) Duplex Jumper (LC<>LC) [RSW<>FSW] Install (A-End/Passive) Duplex Jumper [RSW<>FSW] Not Started 12/16/26 12/17/26 2.5 2.5
0%
145.0
RPL10.WP4.025340 RPL10.Conn NS3.CFD1.03<>03 Install Simplex Jumper at Z- End (SC<>LC) [PON] Install Simplex Jumper [PON] Not Started 12/16/26 12/16/26 1.2 1.2
0%
140.0
RPL10.WP4.031800 RPL10.Conn NS3.CFD5.48<>46-49 Prefab Duplex Jumper (LC<>LC) [RSW<>FSW] Prefab Not Started 12/16/26 12/16/26 1.2 1.2
0%
117.5
RPL10.WP4.033420 RPL10.Conn NS4.CFD2.15 Install (Z-End/Active) Duplex Jumper (LC<>LC) [MA<>JXSW] Install Duplex Jumper [MA<>JXSW] Not Started 12/16/26 12/17/26 2.5 2.5
0%
130.0
RPL10.WP4.034660 RPL10.Conn NS1.CFD1 Pull/Install Ext. Trunk (24F) [DR<>BB] [DR<>BB] Not Started 12/16/26 12/17/26 2.5 2.5
0%
7.5
RPL10.WP4.05700 RPL10.Conn NS3.CFD4.28 Pull Duplex Jumper (LC<>LC) [MA<>JXSW] Pull Duplex Jumper [MA<>JXSW] Not Started 12/16/26 12/18/26 3.8 3.8
0%
121.2
RPL10.EY.EF2.01500 RPL10.EY.EF2 - Install RPL-5 FSP Interior Hilti Support & Cable Trays Fiber Support Platform - RPL-5 Not Started 12/17/26 01/05/27 15.0 15.0
0%
91.2
RPL10.EY.NS4.01410 RPL10.EY.NS4 - Install Remaining CU (2) Build Back Exterior Leave Out Wall #4 (Tent Area) Not Started 12/17/26 12/18/26 2.5 2.5
0%
88.8
RPL10.INT.NS3.01950 RPL10.Interior.NS3 - Control Fault Domain 6 SQ12.2 - L2 Checklist Completion Remaining Tie-ins post Mech Side Aisle install Not Started 12/17/26 01/15/27 25.0 25.0
0%
73.8
RPL10.INT.NS3.03100 RPL10.Interior.NS3 - Control Fault Domain 6 SQ12.2 - Install FA Terminations to Fire Alarm Panel (In Riser Room) Remaining Tie-ins post Mech Side Aisle install Not Started 12/17/26 12/23/26 6.2 6.2
0%
92.5
RPL10.INT.NS4.01760 RPL10.Conn NS4.CFD5 - Set Passive Racks for WP3B Infrastructure Not Started 12/17/26 12/21/26 3.8 3.8
0%
40.0
RPL10.INT.NS4.03040 RPL10.Conn NS4.CFD5 - Set Passive Racks for PON Infrastructure Not Started 12/17/26 12/21/26 3.8 3.8
0%
121.2
RPL10.W3B.FE.011926 RPL10.Conn EF2B<>NS3.CFD3 (P1-4) Install Fiber Trunk (288F) [EF<>JXSW] EF2B<>NS3.3 (P1-4) [EF<>JXSW] Not Started 12/17/26 12/21/26 3.8 3.8
0%
0.0
RPL10.W3B.FE.012461 RPL10.Conn EF1F<>NS4.CFD3 (P2-3) Install Fiber Trunk (384F) [EF<>SSW] EF1F<>NS4.3 (P2-3) [EF<>SSW] Not Started 12/17/26 12/18/26 2.5 2.5
0%
43.8
RPL10.W3B.FE.013066 RPL10.Conn EF1F<>NS4.CFD3 (P2-3) Test Fiber Trunk (288F) [EF<>JXSW] EF1F<>NS4.3 (P2-3) [EF<>JXSW] Not Started 12/17/26 12/18/26 2.5 2.5
0%
53.8
RPL10.W3B.FE.013226 RPL10.Conn EF1F<>NS3.CFD2 (P2-3) Test Fiber Trunk (384F) [EF<>SSW] EF1F<>NS3.2 (P2-3) [EF<>SSW] Not Started 12/17/26 12/18/26 2.5 2.5
0%
15.0
RPL10.WA.EF1.01000 RPL10.WA - OFE to AC - EF1 Weather Allowance Not Started 12/17/26 12/26/26 12.5 12.5
0%
42.5
RPL10.WP4.010100 RPL10.Conn NS2.CFD1.03<>45 Pull/Install Trunk (384F) [MA<>EB] [MA<>EB] Not Started 12/17/26 12/21/26 3.8 3.8
0%
-18.8
RPL10.WP4.014620 RPL10.Conn NS3.CFD4.29<>29 Pull & Install Simplex Jumper at A- End (SC<>LC) [PON] Pull Simplex Jumper [PON] Not Started 12/17/26 12/18/26 2.5 2.5
0%
136.2
RPL10.WP4.014660 RPL10.Conn NS3.CFD4.31<>31 Pull & Install Simplex Jumper at A- End (SC<>LC) [PON] Pull Simplex Jumper [PON] Not Started 12/17/26 12/18/26 2.5 2.5
0%
138.8
RPL10.WP4.015680 RPL10.Conn NS4.CFD5.34<>33 Pull & Install Simplex Jumper at A- End (SC<>LC) [PON] Pull Simplex Jumper [PON] Not Started 12/17/26 12/21/26 3.8 3.8
0%
118.8
RPL10.WP4.015720 RPL10.Conn NS4.CFD5.36<>35 Pull & Install Simplex Jumper at A- End (SC<>LC) [PON] Pull Simplex Jumper [PON] Not Started 12/17/26 12/21/26 3.8 3.8
0%
118.8
RPL10.WP4.019680 RPL10.Conn NS2.CFD1.48<>46-49 Install (A-End/Passive) Duplex Jumper (LC<>LC) [RSW<>FSW] Install (A-End/Passive) Duplex Jumper [RSW<>FSW] Not Started 12/17/26 12/18/26 2.5 2.5
0%
28.8
RPL10.WP4.022060 RPL10.Conn NS4.CFD2.48<>41-44 Install (A-End/Passive) Duplex Jumper (LC<>LC) [RSW<>FSW] Install (A-End/Passive) Duplex Jumper [RSW<>FSW] Not Started 12/17/26 12/18/26 2.5 2.5
0%
128.8
RPL10.WP4.025360 RPL10.Conn NS3.CFD1.04<>03 Install Simplex Jumper at Z- End (SC<>LC) [PON] Install Simplex Jumper [PON] Not Started 12/17/26 12/17/26 1.2 1.2
0%
140.0
RPL10.WP4.06000 RPL10.Conn NS3.CFD5.33 Pull Duplex Jumper (LC<>LC) [MA<>JXSW] Pull Duplex Jumper [MA<>JXSW] Not Started 12/17/26 12/21/26 3.8 3.8
0%
108.8
RPL10.WP4.06160 RPL10.Conn NS3.CFD5.48<>03-05 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] Pull Duplex Jumper [RSW<>FSW] Not Started 12/17/26 12/21/26 3.8 3.8
0%
117.5
RPL10.WP4.06180 RPL10.Conn NS3.CFD5.48<>06-10 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] Pull Duplex Jumper [RSW<>FSW] Not Started 12/17/26 12/21/26 3.8 3.8
0%
118.8
RPL10.WP4.06200 RPL10.Conn NS3.CFD5.48<>11-15 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] Pull Duplex Jumper [RSW<>FSW] Not Started 12/17/26 12/24/26 7.5 7.5
0%
118.8
RPL10.WP4.NS3.01400 RPL10.Conn NS3.CFD1 GSMDF <> Network Suites Management Trunks Post ORv3 Rack Not Started 12/17/26 12/21/26 3.8 3.8
0%
55.0
RPL10.WP4.NS3.03060 RPL10.Conn NS3.CFD4 Infrastructure - WBS Summary Infrastructure Not Started 12/17/26 12/22/26 5.0 5.0
0%
68.8
RPL10.WP4.NS3.03080 RPL10.Conn NS3.CFD4 Infrastructure Infrastructure Not Started 12/17/26 12/22/26 5.0 5.0
0%
68.8
RPL10.Conn.MS.01010 Wifi Ready - All locations Connectivity Milestones Not Started 12/18/26 12/18/26 0.0 0.0
0%
303.8
RPL10.Conn.MS.01450 Wifi Ready - NS3 Connectivity Milestones Not Started 12/18/26 12/18/26 0.0 0.0
0%
303.8
RPL10.ENDC.BB.1980 RPL10.Int.Build Back.End-Corr - LO #10 - Final Punch Walk Build Back Interior Leave Out Wall #10 (End Corr) Not Started 12/18/26 12/21/26 2.5 2.5
0%
123.8
RPL10.ENDC.BB.3265 RPL10.Ext.Build Back.End-Corr - LO #4 - MEPF Trim Out Build Back Exterior Leave Out Wall #4 (Tent Area) Not Started 12/18/26 01/04/27 12.5 12.5
0%
98.8
RPL10.W3B.FE.011391 RPL10.Conn EF2B<>NS4.CFD5 (P1-4) Pull Fiber Trunk (384F) [EF<>SSW] EF2B<>NS4.5 (P1-4) [EF<>SSW] Not Started 12/18/26 12/22/26 3.8 3.8
0%
67.5
RPL10.W3B.FE.011476 RPL10.Conn EF1F<>NS4.CFD5 (P2-3) Pull Fiber Trunk (288F) [EF<>JXSW] EF1F<>NS4.5 (P2-3) [EF<>JXSW] Not Started 12/18/26 12/23/26 5.0 5.0
0%
83.8
RPL10.WP3B.FE.09400 RPL10.Conn EF1F<>NS4.CFD5 (P2-3) Pull/Install/Test - WBS Summary EF1F<>NS4.5 (P2-3) [EF<>JXSW] Not Started 12/18/26 02/18/27 51.2 51.2
0%
43.8
RPL10.WP3B.FE.09500 RPL10.Conn EF2B<>NS4.CFD5 (P1-4) Pull/Install/Test - WBS Summary EF2B<>NS4.5 (P1-4) [EF<>SSW] Not Started 12/18/26 01/29/27 35.0 35.0
0%
47.5
RPL10.WP4.010300 RPL10.Conn NS4.CFD3 Pull/Install Trunk (384F) [RSW<>FSW] Pull/Install Trunk & Multidrop Cable Not Started 12/18/26 12/29/26 8.8 8.8
0%
116.2
RPL10.WP4.025380 RPL10.Conn NS3.CFD1.05<>05 Install Simplex Jumper at Z- End (SC<>LC) [PON] Install Simplex Jumper [PON] Not Started 12/18/26 12/18/26 1.2 1.2
0%
140.0
RPL10.WP4.026580 RPL10.Conn NS4.CFD3.17<>17 Install Simplex Jumper at Z- End (SC<>LC) [PON] Install Simplex Jumper [PON] Not Started 12/18/26 12/18/26 1.2 1.2
0%
122.5
RPL10.WP4.033440 RPL10.Conn NS4.CFD2.16 Install (Z-End/Active) Duplex Jumper (LC<>LC) [MA<>JXSW] Install Duplex Jumper [MA<>JXSW] Not Started 12/18/26 12/21/26 2.5 2.5
0%
130.0
RPL10.WP4.033460 RPL10.Conn NS4.CFD3.17 Install (Z-End/Active) Duplex Jumper (LC<>LC) [MA<>JXSW] Install Duplex Jumper [MA<>JXSW] Not Started 12/18/26 12/21/26 2.5 2.5
0%
112.5
RPL10.WP4.034680 RPL10.Conn NS1.CFD1 Pull Duplex Jumper (LC<>LC) [DR<>BB] [DR<>BB] Not Started 12/18/26 12/18/26 1.2 1.2
0%
7.5
RPL10.WP4.05420 RPL10.Conn NS3.CFD3.24 Pull Duplex Jumper (LC<>LC) [MA<>JXSW] Pull Duplex Jumper [MA<>JXSW] Not Started 12/18/26 12/22/26 3.8 3.8
0%
133.8
RPL10.WP4.06220 RPL10.Conn NS3.CFD5.48<>16-20 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] Pull Duplex Jumper [RSW<>FSW] Not Started 12/18/26 12/24/26 6.2 6.2
0%
121.2
RPL10.WP4.06240 RPL10.Conn NS3.CFD5.48<>21-25 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] Pull Duplex Jumper [RSW<>FSW] Not Started 12/18/26 12/24/26 6.2 6.2
0%
123.8
RPL10.WP4.07900 RPL10.Conn NS4.CFD5.36 Pull Duplex Jumper (LC<>LC) [MA<>JXSW] Pull Duplex Jumper [MA<>JXSW] Not Started 12/18/26 12/22/26 3.8 3.8
0%
106.2
RPL10.WP4.09520 RPL10.Conn NS4.CFD3 Pull/Install Trunk (192F) [FSW<>SSW] Pull/Install Trunk & Multidrop Cable Not Started 12/18/26 12/28/26 7.5 7.5
0%
125.0
RPL10.WP4.NS2.03680 RPL10.Conn NS2.CFD1 Network Suite [JXSW<>MA] Fanouts Post ORv3 Rack Not Started 12/18/26 12/22/26 3.8 3.8
0%
15.0
RPL10.WP4.NS4.01740 RPL10.Conn NS4.CFD4 Network Suite [JXSW<>MA] Multi Drop Cable Pre ORv3 Rack Not Started 12/18/26 12/30/26 10.0 10.0
0%
67.5
RPL10.ENDC.BB.3000 RPL10.Ext.Build Back.End-Corr - LO #3 - Install Remaining Foor Supported Supplemental Steel (See Notes) Build Back Exterior Leave Out Wall #3 (Tent Area) Not Started 12/21/26 12/28/26 6.2 6.2
0%
78.8
RPL10.ENDC.BB.3180 RPL10.Ext.Build Back.End-Corr - LO #3 - Install Frame, Doors, Hardware Build Back Exterior Leave Out Wall #3 (Tent Area) Not Started 12/21/26 12/22/26 2.5 2.5
0%
83.8
RPL10.EY.NS4.01420 RPL10.EY.NS4 - Install Irrigation Hardscape and Landscape Not Started 12/21/26 01/05/27 12.5 12.5
0%
278.8
RPL10.EY.NS4.01430 RPL10.EY.NS4 - Install Exterior Signage Hardscape and Landscape Not Started 12/21/26 01/05/27 12.5 12.5
0%
133.8
RPL10.EY.NS4.01440 RPL10.EY.NS4 - Install Remaining Mechanical Tie-ins Build Back Exterior Leave Out Wall #4 (Tent Area) Not Started 12/21/26 12/28/26 6.2 6.2
0%
88.8
RPL10.EY.NS4.01450 RPL10.EY.NS4 - Install Remaining Electrical Tie-ins Build Back Exterior Leave Out Wall #4 (Tent Area) Not Started 12/21/26 12/28/26 6.2 6.2
0%
88.8
RPL10.INT.NS4.01960 RPL10.Interior.NS4 - Final Clean Tie-Ins Not Started 12/21/26 12/24/26 5.0 5.0
0%
130.0
RPL10.W3B.FE.011756 RPL10.Conn EF2F<>NS3.CFD4 (P1-4) Pull Fiber Trunk (384F) [EF<>SSW] EF2F<>NS3.4 (P1-4) [EF<>SSW] Not Started 12/21/26 12/22/26 2.5 2.5
0%
30.0
RPL10.W3B.FE.011951 RPL10.Conn EF2B<>NS4.CFD4 (P1-4) Install Fiber Trunk (288F) [EF<>JXSW] EF2B<>NS4.4 (P1-4) [EF<>JXSW] Not Started 12/21/26 12/23/26 3.8 3.8
0%
43.8
RPL10.W3B.FE.013261 RPL10.Conn EF1F<>NS4.CFD3 (P2-3) Test Fiber Trunk (384F) [EF<>SSW] EF1F<>NS4.3 (P2-3) [EF<>SSW] Not Started 12/21/26 12/22/26 2.5 2.5
0%
53.8
RPL10.WP3B.FE.08540 RPL10.Conn EF2F<>NS3.CFD4 (P1-4) Pull/Install/Test - WBS Summary EF2F<>NS3.4 (P1-4) [EF<>SSW] Not Started 12/21/26 02/03/27 37.5 37.5
0%
7.5
RPL10.WP4.014640 RPL10.Conn NS3.CFD4.30<>29 Pull & Install Simplex Jumper at A- End (SC<>LC) [PON] Pull Simplex Jumper [PON] Not Started 12/21/26 12/23/26 3.8 3.8
0%
136.2
RPL10.WP4.014680 RPL10.Conn NS3.CFD4.32<>31 Pull & Install Simplex Jumper at A- End (SC<>LC) [PON] Pull Simplex Jumper [PON] Not Started 12/21/26 12/23/26 3.8 3.8
0%
138.8
RPL10.WP4.015840 RPL10.Conn NS4.CFD6.42<>41 Pull & Install Simplex Jumper at A- End (SC<>LC) [PON] Pull Simplex Jumper [PON] Not Started 12/21/26 12/23/26 3.8 3.8
0%
116.2
RPL10.WP4.015880 RPL10.Conn NS4.CFD6.44<>43 Pull & Install Simplex Jumper at A- End (SC<>LC) [PON] Pull Simplex Jumper [PON] Not Started 12/21/26 12/23/26 3.8 3.8
0%
116.2
RPL10.WP4.019900 RPL10.Conn NS3.CFD2.09 Install (A-End/Passive) Duplex Jumper (LC<>LC) [MA<>JXSW] Install (A-End/Passive) Duplex Jumper [MA<>JXSW] Not Started 12/21/26 12/22/26 2.5 2.5
0%
123.8
RPL10.WP4.020060 RPL10.Conn NS3.CFD2.48<>03-05 Install (A-End/Passive) Duplex Jumper (LC<>LC) [RSW<>FSW] Install (A-End/Passive) Duplex Jumper [RSW<>FSW] Not Started 12/21/26 12/22/26 2.5 2.5
0%
118.8
RPL10.WP4.022080 RPL10.Conn NS4.CFD2.48<>46-49 Install (A-End/Passive) Duplex Jumper (LC<>LC) [RSW<>FSW] Install (A-End/Passive) Duplex Jumper [RSW<>FSW] Not Started 12/21/26 12/22/26 2.5 2.5
0%
128.8
RPL10.WP4.025400 RPL10.Conn NS3.CFD1.06<>05 Install Simplex Jumper at Z- End (SC<>LC) [PON] Install Simplex Jumper [PON] Not Started 12/21/26 12/21/26 1.2 1.2
0%
140.0
RPL10.WP4.026600 RPL10.Conn NS4.CFD3.18<>17 Install Simplex Jumper at Z- End (SC<>LC) [PON] Install Simplex Jumper [PON] Not Started 12/21/26 12/21/26 1.2 1.2
0%
122.5
RPL10.WP4.031920 RPL10.Conn NS3.CFD6.48<>26-30 Prefab Duplex Jumper (LC<>LC) [RSW<>FSW] Prefab Not Started 12/21/26 12/24/26 5.0 5.0
0%
55.0
RPL10.WP4.034700 RPL10.Conn NS1.CFD1 Pull/Install In-Rack Fanout (LC<>MMC) [DR<>BB] [DR<>BB] Not Started 12/21/26 12/22/26 2.5 2.5
0%
7.5
RPL10.WP4.034720 RPL10.Conn NS1.CFD1 Install Duplex Jumper (LC<>LC) [DR<>BB] [DR<>BB] Not Started 12/21/26 12/22/26 2.5 2.5
0%
15.0
RPL10.WP4.05720 RPL10.Conn NS3.CFD4.29 Pull Duplex Jumper (LC<>LC) [MA<>JXSW] Pull Duplex Jumper [MA<>JXSW] Not Started 12/21/26 12/23/26 3.8 3.8
0%
121.2
RPL10.WP4.06260 RPL10.Conn NS3.CFD5.48<>26-30 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] Pull Duplex Jumper [RSW<>FSW] Not Started 12/21/26 12/24/26 5.0 5.0
0%
126.2
RPL10.WP4.06280 RPL10.Conn NS3.CFD5.48<>31-35 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] Pull Duplex Jumper [RSW<>FSW] Not Started 12/21/26 12/24/26 5.0 5.0
0%
128.8
RPL10.WP4.NS3.02200 RPL10.Conn NS3.CFD3 Network Suite [JXSW<>MA] Multi Drop Cable Pre ORv3 Rack Not Started 12/21/26 12/31/26 10.0 10.0
0%
53.8
RPL10.WP4.NS4.01580 RPL10.Conn NS4.CFD3 Network Suite [JXSW<>MA] Fanouts Post ORv3 Rack Not Started 12/21/26 12/31/26 10.0 10.0
0%
51.2
RPL10.WP4.NS4.02880 RPL10.Conn NS4.CFD4 - Install ORv3 OFE - Passive In-row Racks, Racks (ORv3Ns, MCRs) & PON Not Started 12/21/26 12/30/26 8.8 8.8
0%
73.8