Last schedule upload: D3-R25005-00-RPL10 — 8463 activities — 05/05/2026 09:13 AM CT
RPL10 - GC LIVE SCHEDULE - Data Date 20260426.xer
· Uploaded May 05, 2026 02:13 PM
· 8463 activities
Experimental
Auto-populate checklist dates from schedule:
100
Activities Shown
0
Completed
0
In Progress
1
Critical
| Activity ID | Activity Name | WBS | Status | Start | Finish | Dur (d) | Rem (d) | % Comp | Float (d) |
|---|---|---|---|---|---|---|---|---|---|
RPL10.ENDC.BB.3320 |
RPL10.Ext.Build Back.End-Corr - LO #4 - Install Plumbing | Build Back Exterior Leave Out Wall #4 (Tent Area) | Not Started | 12/04/26 | 12/10/26 | 6.2 | 6.2 |
|
105.0 |
RPL10.ENDC.BB.3325 |
RPL10.Ext.Build Back.End-Corr - LO #4 - Install Security | Build Back Exterior Leave Out Wall #4 (Tent Area) | Not Started | 12/04/26 | 12/10/26 | 6.2 | 6.2 |
|
105.0 |
RPL10.ENDC.BB.3330 |
RPL10.Ext.Build Back.End-Corr - LO #4 - Install VAV's/Duct Branches | Build Back Exterior Leave Out Wall #4 (Tent Area) | Not Started | 12/04/26 | 12/10/26 | 6.2 | 6.2 |
|
105.0 |
RPL10.ENDC.BB.3335 |
RPL10.Ext.Build Back.End-Corr - LO #4 - Install Split Systems/Humidifiers | Build Back Exterior Leave Out Wall #4 (Tent Area) | Not Started | 12/04/26 | 12/10/26 | 6.2 | 6.2 |
|
105.0 |
RPL10.ENDC.BB.3340 |
RPL10.Ext.Build Back.End-Corr - LO #4 - Install Electrical | Build Back Exterior Leave Out Wall #4 (Tent Area) | Not Started | 12/04/26 | 12/10/26 | 6.2 | 6.2 |
|
105.0 |
RPL10.ENDC.BB.3345 |
RPL10.Ext.Build Back.End-Corr - LO #4 - Install Controls / EPMS / BMS | Build Back Exterior Leave Out Wall #4 (Tent Area) | Not Started | 12/04/26 | 12/10/26 | 6.2 | 6.2 |
|
105.0 |
RPL10.ENDC.BB.3350 |
RPL10.Ext.Build Back.End-Corr - LO #4 - Install Refrigerant Piping | Build Back Exterior Leave Out Wall #4 (Tent Area) | Not Started | 12/04/26 | 12/17/26 | 12.5 | 12.5 |
|
98.8 |
RPL10.ENDC.BB.3365 |
RPL10.Ext.Build Back.End-Corr - LO #4 - Install Fire Sprinkler | Build Back Exterior Leave Out Wall #4 (Tent Area) | Not Started | 12/04/26 | 12/09/26 | 5.0 | 5.0 |
|
106.2 |
RPL10.ORV3.010420 |
OFE - Delivery ROJ: ORv3 for CFD NS3.3 (ROJ 12.14.26) (RVCD 11.16.26) | NS3 | Not Started | 12/04/26 | 12/24/26 | 18.8 | 18.8 |
|
50.0 |
RPL10.W3B.FE.011441 |
RPL10.Conn EF1F<>NS3.CFD2 (P2-3) Pull Fiber Trunk (288F) [EF<>JXSW] | EF1F<>NS3.2 (P2-3) [EF<>JXSW] | Not Started | 12/04/26 | 12/09/26 | 5.0 | 5.0 |
|
0.0 |
RPL10.W3B.FE.011551 |
RPL10.Conn EF2F<>NS4.CFD4 (P1-4) Pull Fiber Trunk (288F) [EF<>JXSW] | EF2F<>NS4.4 (P1-4) [EF<>JXSW] | Not Started | 12/04/26 | 12/09/26 | 5.0 | 5.0 |
|
58.8 |
RPL10.WP3B.FE.02660 |
RPL10.Conn EF2F<>NS4.CFD4 (P1-4) Pull/Install/Test - WBS Summary* | EF2F<>NS4.4 (P1-4) [EF<>JXSW] | Not Started | 12/04/26 | 01/05/27 | 26.2 | 26.2 |
|
51.2 |
RPL10.WP3B.FE.08260 |
RPL10.Conn EF1F<>NS3.CFD2 (P2-3) Pull/Install/Test - WBS Summary | EF1F<>NS3.2 (P2-3) [EF<>JXSW] | Not Started | 12/04/26 | 12/16/26 | 11.2 | 11.2 |
|
15.0 |
RPL10.WP4.017620 |
RPL10.Conn NS1.CFD2.48<>46-49 Install (A-End/Passive) Duplex Jumper (LC<>LC) [RSW<>FSW] | Install (A-End/Passive) Duplex Jumper [RSW<>FSW] | Not Started | 12/04/26 | 12/07/26 | 2.5 | 2.5 |
|
28.8 |
RPL10.WP4.017740 |
RPL10.Conn NS1.CFD1.48<>26-30 Install (A-End/Passive) Duplex Jumper (LC<>LC) [RSW<>FSW] | Install (A-End/Passive) Duplex Jumper [RSW<>FSW] | Not Started | 12/04/26 | 12/07/26 | 2.5 | 2.5 |
|
18.8 |
RPL10.WP4.019800 |
RPL10.Conn NS3.CFD1.48<>26-30 Install (A-End/Passive) Duplex Jumper (LC<>LC) [RSW<>FSW] | Install (A-End/Passive) Duplex Jumper [RSW<>FSW] | Not Started | 12/04/26 | 12/07/26 | 2.5 | 2.5 |
|
145.0 |
RPL10.WP4.026500 |
RPL10.Conn NS4.CFD2.13<>13 Install Simplex Jumper at Z- End (SC<>LC) [PON] | Install Simplex Jumper [PON] | Not Started | 12/04/26 | 12/04/26 | 1.2 | 1.2 |
|
140.0 |
RPL10.WP4.030600 |
RPL10.Conn NS4.CFD5.48<>46-49 Prefab Duplex Jumper (LC<>LC) [RSW<>FSW] | Prefab | Not Started | 12/04/26 | 12/04/26 | 1.2 | 1.2 |
|
115.0 |
RPL10.WP4.030800 |
RPL10.Conn NS4.CFD6.48<>46-49 Prefab Duplex Jumper (LC<>LC) [RSW<>FSW] | Prefab | Not Started | 12/04/26 | 12/04/26 | 1.2 | 1.2 |
|
115.0 |
RPL10.WP4.031740 |
RPL10.Conn NS3.CFD5.48<>31-35 Prefab Duplex Jumper (LC<>LC) [RSW<>FSW] | Prefab | Not Started | 12/04/26 | 12/08/26 | 3.8 | 3.8 |
|
117.5 |
RPL10.WP4.033340 |
RPL10.Conn NS4.CFD2.11 Install (Z-End/Active) Duplex Jumper (LC<>LC) [MA<>JXSW] | Install Duplex Jumper [MA<>JXSW] | Not Started | 12/04/26 | 12/07/26 | 2.5 | 2.5 |
|
130.0 |
RPL10.WP4.05060 |
RPL10.Conn NS3.CFD2.16 Pull Duplex Jumper (LC<>LC) [MA<>JXSW] | Pull Duplex Jumper [MA<>JXSW] | Not Started | 12/04/26 | 12/08/26 | 3.8 | 3.8 |
|
146.2 |
RPL10.WP4.NS2.03200 |
RPL10.Conn NS2.CFD2 Network Suite Management and Console In - Rack Fanout - PON | Post ORv3 Rack | Not Started | 12/04/26 | 12/15/26 | 10.0 | 10.0 |
|
32.5 |
GCD.RPL10.4585 |
L3 Finish - NS2 | NS | Not Started | 12/07/26 | 12/07/26 | 0.0 | 0.0 |
|
23.8 |
GCD.RPL10.5605 |
[RPL10] FacNet Live RPL10 - All Exterior IDF huts | TC Ready: FacNet Live | Not Started | 12/07/26 | 12/07/26 | 0.0 | 0.0 |
|
56.2 |
RPL10.CX.NS4.01110 |
RPL10.CX.NS4 - L3/L4 - Control Fault Domain 2 | NS4 Control Fault Domain 2 | Not Started | 12/07/26 | 12/29/26 | 20.0 | 20.0 |
|
36.2 |
RPL10.Conn.MS.01090 |
CorpNet & FacNet Available - NS3 | Network Suite 3 | Not Started | 12/07/26 | 12/07/26 | 0.0 | 0.0 |
|
56.2 |
RPL10.ENDC.BB.3370 |
RPL10.Ext.Build Back.End-Corr - LO #4 - Tape Finish Paint | Build Back Exterior Leave Out Wall #4 (Tent Area) | Not Started | 12/07/26 | 12/11/26 | 6.2 | 6.2 |
|
103.8 |
RPL10.EY.NS4.01380 |
RPL10.EY.NS4 - Install F/R/P Remaining Equipment Pads | Build Back Exterior Leave Out Wall #4 (Tent Area) | Not Started | 12/07/26 | 12/11/26 | 6.2 | 6.2 |
|
90.0 |
RPL10.INT.NS3.01760 |
RPL10.Conn NS3.CFD5 - Set Passive Racks for WP3B | Infrastructure | Not Started | 12/07/26 | 12/09/26 | 3.8 | 3.8 |
|
70.0 |
RPL10.INT.NS3.01900 |
RPL10.Conn NS3.CFD6 - Set Passive Racks for WP3B | Infrastructure | Not Started | 12/07/26 | 12/09/26 | 3.8 | 3.8 |
|
97.5 |
RPL10.INT.NS3.03060 |
RPL10.Conn NS3.CFD5 - Set Passive Racks for PON | Infrastructure | Not Started | 12/07/26 | 12/09/26 | 3.8 | 3.8 |
|
116.2 |
RPL10.INT.NS3.03080 |
RPL10.Conn NS3.CFD6 - Set Passive Racks for PON | Infrastructure | Not Started | 12/07/26 | 12/09/26 | 3.8 | 3.8 |
|
118.8 |
RPL10.W3B.FE.011751 |
RPL10.Conn EF2F<>NS3.CFD3 (P1-4) Pull Fiber Trunk (384F) [EF<>SSW] | EF2F<>NS3.3 (P1-4) [EF<>SSW] | Not Started | 12/07/26 | 12/08/26 | 2.5 | 2.5 |
|
17.5 |
RPL10.W3B.FE.011866 |
RPL10.Conn EF1B<>NS4.CFD3 (P2-3) Install Fiber Trunk (288F) [EF<>JXSW] | EF1B<>NS4.3 (P2-3) [EF<>JXSW] | Not Started | 12/07/26 | 12/09/26 | 3.8 | 3.8 |
|
43.8 |
RPL10.W3B.FE.012026 |
RPL10.Conn EF1B<>NS3.CFD2 (P2-3) Install Fiber Trunk (384F) [EF<>SSW] | EF1B<>NS3.2 (P2-3) [EF<>SSW] | Not Started | 12/07/26 | 12/08/26 | 2.5 | 2.5 |
|
1.2 |
RPL10.W3B.FE.012641 |
RPL10.Conn EF1B<>NS3.CFD2 (P2-3) Test Fiber Trunk (288F) [EF<>JXSW] | EF1B<>NS3.2 (P2-3) [EF<>JXSW] | Not Started | 12/07/26 | 12/08/26 | 2.5 | 2.5 |
|
17.5 |
RPL10.W3B.FE.013381 |
RPL10.Conn EF2F<>NS4.CFD3 (P1-4) Test Fiber Trunk (384F) [EF<>SSW] | EF2F<>NS4.3 (P1-4) [EF<>SSW] | Not Started | 12/07/26 | 12/08/26 | 2.5 | 2.5 |
|
56.2 |
RPL10.WP2.01180 |
RPL10.Conn CorpNet & FacNet Available (All locations) | WP2 (GS/CARRIER/SFZ - INF, CAB [ISP/OSP], NET) | Not Started | 12/07/26 | 12/07/26 | 0.0 | 0.0 |
|
56.2 |
RPL10.WP3B.FE.08380 |
RPL10.Conn EF2F<>NS3.CFD3 (P1-4) Pull/Install/Test - WBS Summary | EF2F<>NS3.3 (P1-4) [EF<>SSW] | Not Started | 12/07/26 | 01/05/27 | 25.0 | 25.0 |
|
12.5 |
RPL10.WP4.014480 |
RPL10.Conn NS3.CFD3.22<>21 Pull & Install Simplex Jumper at A- End (SC<>LC) [PON] | Pull Simplex Jumper [PON] | Not Started | 12/07/26 | 12/09/26 | 3.8 | 3.8 |
|
148.8 |
RPL10.WP4.014520 |
RPL10.Conn NS3.CFD3.24<>23 Pull & Install Simplex Jumper at A- End (SC<>LC) [PON] | Pull Simplex Jumper [PON] | Not Started | 12/07/26 | 12/09/26 | 3.8 | 3.8 |
|
151.2 |
RPL10.WP4.019480 |
RPL10.Conn NS2.CFD2.48<>46-49 Install (A-End/Passive) Duplex Jumper (LC<>LC) [RSW<>FSW] | Install (A-End/Passive) Duplex Jumper [RSW<>FSW] | Not Started | 12/07/26 | 12/08/26 | 2.5 | 2.5 |
|
38.8 |
RPL10.WP4.019600 |
RPL10.Conn NS2.CFD1.48<>26-30 Install (A-End/Passive) Duplex Jumper (LC<>LC) [RSW<>FSW] | Install (A-End/Passive) Duplex Jumper [RSW<>FSW] | Not Started | 12/07/26 | 12/08/26 | 2.5 | 2.5 |
|
28.8 |
RPL10.WP4.021820 |
RPL10.Conn NS4.CFD2.13 Install (A-End/Passive) Duplex Jumper (LC<>LC) [MA<>JXSW] | Install (A-End/Passive) Duplex Jumper [MA<>JXSW] | Not Started | 12/07/26 | 12/08/26 | 2.5 | 2.5 |
|
133.8 |
RPL10.WP4.021980 |
RPL10.Conn NS4.CFD2.48<>21-25 Install (A-End/Passive) Duplex Jumper (LC<>LC) [RSW<>FSW] | Install (A-End/Passive) Duplex Jumper [RSW<>FSW] | Not Started | 12/07/26 | 12/08/26 | 2.5 | 2.5 |
|
128.8 |
RPL10.WP4.026520 |
RPL10.Conn NS4.CFD2.14<>13 Install Simplex Jumper at Z- End (SC<>LC) [PON] | Install Simplex Jumper [PON] | Not Started | 12/07/26 | 12/07/26 | 1.2 | 1.2 |
|
140.0 |
RPL10.WP4.031600 |
RPL10.Conn NS3.CFD4.48<>46-49 Prefab Duplex Jumper (LC<>LC) [RSW<>FSW] | Prefab | Not Started | 12/07/26 | 12/07/26 | 1.2 | 1.2 |
|
126.2 |
RPL10.WP4.05360 |
RPL10.Conn NS3.CFD3.21 Pull Duplex Jumper (LC<>LC) [MA<>JXSW] | Pull Duplex Jumper [MA<>JXSW] | Not Started | 12/07/26 | 12/09/26 | 3.8 | 3.8 |
|
133.8 |
RPL10.WP4.07600 |
RPL10.Conn NS4.CFD4.31 Pull Duplex Jumper (LC<>LC) [MA<>JXSW] | Pull Duplex Jumper [MA<>JXSW] | Not Started | 12/07/26 | 12/09/26 | 3.8 | 3.8 |
|
128.8 |
RPL10.WP4.07840 |
RPL10.Conn NS4.CFD5.33 Pull Duplex Jumper (LC<>LC) [MA<>JXSW] | Pull Duplex Jumper [MA<>JXSW] | Not Started | 12/07/26 | 12/09/26 | 3.8 | 3.8 |
|
106.2 |
RPL10.WP4.08000 |
RPL10.Conn NS4.CFD5.48<>03-05 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] | Pull Duplex Jumper [RSW<>FSW] | Not Started | 12/07/26 | 12/09/26 | 3.8 | 3.8 |
|
115.0 |
RPL10.WP4.08020 |
RPL10.Conn NS4.CFD5.48<>06-10 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] | Pull Duplex Jumper [RSW<>FSW] | Not Started | 12/07/26 | 12/10/26 | 5.0 | 5.0 |
|
116.2 |
RPL10.WP4.08040 |
RPL10.Conn NS4.CFD5.48<>11-15 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] | Pull Duplex Jumper [RSW<>FSW] | Not Started | 12/07/26 | 12/14/26 | 7.5 | 7.5 |
|
116.2 |
RPL10.WP4.08200 |
RPL10.Conn NS4.CFD6.48<>03-05 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] | Pull Duplex Jumper [RSW<>FSW] | Not Started | 12/07/26 | 12/09/26 | 3.8 | 3.8 |
|
115.0 |
RPL10.WP4.08220 |
RPL10.Conn NS4.CFD6.48<>06-10 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] | Pull Duplex Jumper [RSW<>FSW] | Not Started | 12/07/26 | 12/10/26 | 5.0 | 5.0 |
|
116.2 |
RPL10.WP4.08240 |
RPL10.Conn NS4.CFD6.48<>11-15 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] | Pull Duplex Jumper [RSW<>FSW] | Not Started | 12/07/26 | 12/14/26 | 7.5 | 7.5 |
|
116.2 |
RPL10.WP4.08720 |
RPL10.Conn NS1.CFD1 Pull/Install Ext. Trunk (24F) [EB<>DR] | [EB<>DR] | Not Started | 12/07/26 | 12/09/26 | 3.8 | 3.8 |
|
7.5 |
RPL10.WP4.NS3.01780 |
RPL10.Conn NS3.CFD2 Network Suite [JXSW<>MA] Multi Drop Cable | Pre ORv3 Rack | Not Started | 12/07/26 | 12/16/26 | 10.0 | 10.0 |
|
51.2 |
RPL10.WP4.NS4.03100 |
RPL10.Conn NS4.CFD5 Infrastructure - WBS Summary | Infrastructure | Not Started | 12/07/26 | 12/10/26 | 5.0 | 5.0 |
|
66.2 |
RPL10.WP4.NS4.03120 |
RPL10.Conn NS4.CFD5 Infrastructure | Infrastructure | Not Started | 12/07/26 | 12/10/26 | 5.0 | 5.0 |
|
66.2 |
RPL10.WP4.NS4.03580 |
RPL10.Conn NS4.CFD6 Infrastructure - WBS Summary | Infrastructure | Not Started | 12/07/26 | 12/10/26 | 5.0 | 5.0 |
|
103.8 |
RPL10.WP4.NS4.03600 |
RPL10.Conn NS4.CFD6 Infrastructure | Infrastructure | Not Started | 12/07/26 | 12/10/26 | 5.0 | 5.0 |
|
103.8 |
RPL10.CX.NS2.01200 |
RPL10.CX.NS2 - TAB Verification | NS2 DATA HALL LEVEL TESTING | Not Started | 12/08/26 | 12/14/26 | 6.2 | 6.2 |
|
17.5 |
RPL10.Conn.MS.01470 |
Wifi Ready - NS4 | Connectivity Milestones | Not Started | 12/08/26 | 12/08/26 | 0.0 | 0.0 |
|
313.8 |
RPL10.ENDC.BB.1120 |
RPL10.Ext.Build Back.End-Corr - LO #3 - Install Waterproofing and Flashing | Build Back Exterior Leave Out Wall #3 (Tent Area) | Not Started | 12/08/26 | 12/10/26 | 3.8 | 3.8 |
|
78.8 |
RPL10.ENDC.BB.2980 |
RPL10.Int.Build Back.End-Corr - LO #11 - MEPF - On-Wall, OH, Lowside, Lights | Build Back Interior Leave Out Wall #11 (End Corr) | Not Started | 12/08/26 | 12/29/26 | 18.8 | 18.8 |
|
103.8 |
RPL10.W3B.FE.011666 |
RPL10.Conn EF1F<>NS4.CFD4 (P2-3) Pull Fiber Trunk (384F) [EF<>SSW] | EF1F<>NS4.4 (P2-3) [EF<>SSW] | Not Started | 12/08/26 | 12/09/26 | 2.5 | 2.5 |
|
75.0 |
RPL10.WP2.02800 |
RPL10.Conn GSMDF1<>NS3.CFD4 LVA Pull, Install, & Patch PON Trunks | GSMDF1 <> NS3 - LV side | Not Started | 12/08/26 | 12/09/26 | 2.5 | 2.5 |
|
131.2 |
RPL10.WP2.02920 |
RPL10.Conn GSMDF2<>NS3.CFD4 MSA Pull, Install, & Patch PON Trunks | GSMDF2 <> NS3 - MES side | Not Started | 12/08/26 | 12/09/26 | 2.5 | 2.5 |
|
131.2 |
RPL10.WP4.017760 |
RPL10.Conn NS1.CFD1.48<>31-35 Install (A-End/Passive) Duplex Jumper (LC<>LC) [RSW<>FSW] | Install (A-End/Passive) Duplex Jumper [RSW<>FSW] | Not Started | 12/08/26 | 12/09/26 | 2.5 | 2.5 |
|
18.8 |
RPL10.WP4.019820 |
RPL10.Conn NS3.CFD1.48<>31-35 Install (A-End/Passive) Duplex Jumper (LC<>LC) [RSW<>FSW] | Install (A-End/Passive) Duplex Jumper [RSW<>FSW] | Not Started | 12/08/26 | 12/09/26 | 2.5 | 2.5 |
|
145.0 |
RPL10.WP4.026540 |
RPL10.Conn NS4.CFD2.15<>15 Install Simplex Jumper at Z- End (SC<>LC) [PON] | Install Simplex Jumper [PON] | Not Started | 12/08/26 | 12/08/26 | 1.2 | 1.2 |
|
140.0 |
RPL10.WP4.033360 |
RPL10.Conn NS4.CFD2.12 Install (Z-End/Active) Duplex Jumper (LC<>LC) [MA<>JXSW] | Install Duplex Jumper [MA<>JXSW] | Not Started | 12/08/26 | 12/09/26 | 2.5 | 2.5 |
|
130.0 |
RPL10.WP4.05660 |
RPL10.Conn NS3.CFD4.26 Pull Duplex Jumper (LC<>LC) [MA<>JXSW] | Pull Duplex Jumper [MA<>JXSW] | Not Started | 12/08/26 | 12/10/26 | 3.8 | 3.8 |
|
121.2 |
RPL10.WP4.05800 |
RPL10.Conn NS3.CFD4.48<>03-05 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] | Pull Duplex Jumper [RSW<>FSW] | Not Started | 12/08/26 | 12/10/26 | 3.8 | 3.8 |
|
126.2 |
RPL10.WP4.05820 |
RPL10.Conn NS3.CFD4.48<>06-10 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] | Pull Duplex Jumper [RSW<>FSW] | Not Started | 12/08/26 | 12/10/26 | 3.8 | 3.8 |
|
128.8 |
RPL10.WP4.05840 |
RPL10.Conn NS3.CFD4.48<>11-15 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] | Pull Duplex Jumper [RSW<>FSW] | Not Started | 12/08/26 | 12/14/26 | 6.2 | 6.2 |
|
128.8 |
RPL10.WP4.07260 |
RPL10.Conn NS4.CFD3.24 Pull Duplex Jumper (LC<>LC) [MA<>JXSW] | Pull Duplex Jumper [MA<>JXSW] | Not Started | 12/08/26 | 12/10/26 | 3.8 | 3.8 |
|
131.2 |
RPL10.WP4.08060 |
RPL10.Conn NS4.CFD5.48<>16-20 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] | Pull Duplex Jumper [RSW<>FSW] | Not Started | 12/08/26 | 12/14/26 | 6.2 | 6.2 |
|
118.8 |
RPL10.WP4.08080 |
RPL10.Conn NS4.CFD5.48<>21-25 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] | Pull Duplex Jumper [RSW<>FSW] | Not Started | 12/08/26 | 12/14/26 | 6.2 | 6.2 |
|
121.2 |
RPL10.WP4.08260 |
RPL10.Conn NS4.CFD6.48<>16-20 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] | Pull Duplex Jumper [RSW<>FSW] | Not Started | 12/08/26 | 12/14/26 | 6.2 | 6.2 |
|
118.8 |
RPL10.WP4.08280 |
RPL10.Conn NS4.CFD6.48<>21-25 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] | Pull Duplex Jumper [RSW<>FSW] | Not Started | 12/08/26 | 12/14/26 | 6.2 | 6.2 |
|
121.2 |
RPL10.WP4.NS2.02900 |
RPL10.Conn NS2.CFD3 Network Suite Management and Console In - Rack Fanout - PON | Post ORv3 Rack | Not Started | 12/08/26 | 12/17/26 | 10.0 | 10.0 |
|
15.0 |
RPL10.WP4.NS4.01700 |
RPL10.Conn NS4.CFD4 Network - WBS Summary | Network | Not Started | 12/08/26 | 03/05/27 | 75.0 | 75.0 |
|
52.5 |
RPL10.WP4.NS4.01720 |
RPL10.Conn NS4.CFD4 Network Suite [JXSW<>MA] Trunks | Pre ORv3 Rack | Not Started | 12/08/26 | 12/17/26 | 10.0 | 10.0 |
|
67.5 |
GCD.RPL10.5065 |
L3/L4 Finish - NS4 Rows 1-8 | NS | Not Started | 12/09/26 | 12/09/26 | 0.0 | 0.0 |
|
123.8 |
RPL10.CBL.NIDF.03270 |
RPL10.Conn NS3.CFD4 (FE) ISP Cabling - WBS Summary | FENW (Front End Network) | Not Started | 12/09/26 | 02/18/27 | 60.0 | 60.0 |
|
5.0 |
RPL10.CX.NS4.01580 |
RPL10.CX.NS4 - L3/L4 - Control Fault Domain 4 - TW Flush and Fill | NS4 Control Fault Domain 4 | Not Started | 12/09/26 | 12/18/26 | 10.0 | 10.0 |
|
72.5 |
RPL10.W3B.FE.011131 |
RPL10.Conn EF2B<>NS3.CFD4 (P1-4) Pull Fiber Trunk (288F) [EF<>JXSW] | EF2B<>NS3.4 (P1-4) [EF<>JXSW] | Not Started | 12/09/26 | 12/11/26 | 3.8 | 3.8 |
|
28.8 |
RPL10.W3B.FE.012826 |
RPL10.Conn EF1B<>NS3.CFD2 (P2-3) Test Fiber Trunk (384F) [EF<>SSW] | EF1B<>NS3.2 (P2-3) [EF<>SSW] | Not Started | 12/09/26 | 12/10/26 | 2.5 | 2.5 |
|
17.5 |
RPL10.WP3B.FE.08520 |
RPL10.Conn EF2B<>NS3.CFD4 (P1-4) Pull/Install/Test - WBS Summary* | EF2B<>NS3.4 (P1-4) [EF<>JXSW] | Not Started | 12/09/26 | 01/25/27 | 38.8 | 38.8 |
|
8.8 |
RPL10.WP4.012060 |
RPL10.Conn NS4.CFD2 Pull/Install/Test Multidrop Cable (288F) [EF<>JXSW] | Pull/Install Trunk & Multidrop Cable | Not Started | 12/09/26 | 12/16/26 | 7.5 | 7.5 |
|
133.8 |
RPL10.WP4.019620 |
RPL10.Conn NS2.CFD1.48<>31-35 Install (A-End/Passive) Duplex Jumper (LC<>LC) [RSW<>FSW] | Install (A-End/Passive) Duplex Jumper [RSW<>FSW] | Not Started | 12/09/26 | 12/10/26 | 2.5 | 2.5 |
|
28.8 |
RPL10.WP4.021840 |
RPL10.Conn NS4.CFD2.14 Install (A-End/Passive) Duplex Jumper (LC<>LC) [MA<>JXSW] | Install (A-End/Passive) Duplex Jumper [MA<>JXSW] | Not Started | 12/09/26 | 12/10/26 | 2.5 | 2.5 |
|
133.8 |
RPL10.WP4.022000 |
RPL10.Conn NS4.CFD2.48<>26-30 Install (A-End/Passive) Duplex Jumper (LC<>LC) [RSW<>FSW] | Install (A-End/Passive) Duplex Jumper [RSW<>FSW] | Not Started | 12/09/26 | 12/10/26 | 2.5 | 2.5 |
|
128.8 |
RPL10.WP4.026560 |
RPL10.Conn NS4.CFD2.16<>15 Install Simplex Jumper at Z- End (SC<>LC) [PON] | Install Simplex Jumper [PON] | Not Started | 12/09/26 | 12/09/26 | 1.2 | 1.2 |
|
140.0 |
RPL10.WP4.031760 |
RPL10.Conn NS3.CFD5.48<>36-40 Prefab Duplex Jumper (LC<>LC) [RSW<>FSW] | Prefab | Not Started | 12/09/26 | 12/11/26 | 3.8 | 3.8 |
|
117.5 |
RPL10.WP4.031880 |
RPL10.Conn NS3.CFD6.48<>16-20 Prefab Duplex Jumper (LC<>LC) [RSW<>FSW] | Prefab | Not Started | 12/09/26 | 12/14/26 | 5.0 | 5.0 |
|
55.0 |
RPL10.WP4.05860 |
RPL10.Conn NS3.CFD4.48<>16-20 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] | Pull Duplex Jumper [RSW<>FSW] | Not Started | 12/09/26 | 12/14/26 | 5.0 | 5.0 |
|
131.2 |