Schedule Viewer
Last schedule upload: D3-R25005-00-RPL10 — 8463 activities — 05/05/2026 09:13 AM CT
RPL10 - GC LIVE SCHEDULE - Data Date 20260426.xer
· Uploaded May 05, 2026 02:13 PM
· 8463 activities
Experimental
Auto-populate checklist dates from schedule:
100
Activities Shown
0
Completed
0
In Progress
3
Critical
| Activity ID | Activity Name | WBS | Status | Start | Finish | Dur (d) | Rem (d) | % Comp | Float (d) |
|---|---|---|---|---|---|---|---|---|---|
RPL10.WP4.033060 |
RPL10.Conn NS2.CFD3.29 Install (Z-End/Active) Duplex Jumper (LC<>LC) [MA<>JXSW] | Install Duplex Jumper [MA<>JXSW] | Not Started | 10/06/26 | 10/07/26 | 2.5 | 2.5 |
|
82.5 |
RPL10.WP4.06660 |
RPL10.Conn NS4.CFD1.48<>26-30 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] | Pull Duplex Jumper [RSW<>FSW] | Not Started | 10/06/26 | 10/09/26 | 5.0 | 5.0 |
|
177.5 |
RPL10.WP4.06680 |
RPL10.Conn NS4.CFD1.48<>31-35 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] | Pull Duplex Jumper [RSW<>FSW] | Not Started | 10/06/26 | 10/09/26 | 5.0 | 5.0 |
|
180.0 |
RPL10.WP4.09100 |
RPL10.Conn NS1.CFD2 Pull/Install Trunk (192F) [FSW<>SSW] | Pull/Install Trunk & Multidrop Cable | Not Started | 10/06/26 | 10/13/26 | 7.5 | 7.5 |
|
73.8 |
RPL10.WP4.09800 |
RPL10.Conn NS1.CFD2 Pull/Install Trunk (384F) [RSW<>FSW] | Pull/Install Trunk & Multidrop Cable | Not Started | 10/06/26 | 10/13/26 | 7.5 | 7.5 |
|
52.5 |
RPL10.WP4.NS2.02540 |
RPL10.Conn NS2.CFD5 Network Suite Management and Console In - Rack Fanout - PON | Post ORv3 Rack | Not Started | 10/06/26 | 10/15/26 | 10.0 | 10.0 |
|
27.5 |
RPL10.WP4.NS2.02700 |
RPL10.Conn NS2.CFD4 Network Suite Management and Console In - Row Cabling - PON | Post ORv3 Rack | Not Started | 10/06/26 | 10/15/26 | 10.0 | 10.0 |
|
32.5 |
RPL10.CBL.NIDF.02990 |
RPL10.Conn NS4.CFD1 (FE) ISP Cabling - WBS Summary | FENW (Front End Network) | Not Started | 10/07/26 | 10/22/26 | 15.0 | 15.0 |
|
63.8 |
RPL10.CX.NS2.01180 |
RPL10.CX.NS2 - L3/L4 - Elec. Domain 02/01 | NS2 ELECTRICAL | Not Started | 10/07/26 | 10/12/26 | 5.0 | 5.0 |
|
-13.8 |
RPL10.CX.NS2.01520 |
RPL10.CX.NS2 - L3/L4 - Control Fault Domain 2 - TW Flush and Fill | NS2 Control Fault Domain 2 | Not Started | 10/07/26 | 10/16/26 | 10.0 | 10.0 |
|
-18.8 |
RPL10.INT.NS3.01240 |
RPL10.Interior.NS3 - Control Fault Domain 1 SQ7.2 - Install copper from GS.IDF to BMS and EPMS panels | Remaining Tie-ins post Mech Side Aisle install | Not Started | 10/07/26 | 11/03/26 | 25.0 | 25.0 |
|
45.0 |
RPL10.INT.NS4.01500 |
RPL10.Interior.NS4 - Control Fault Domain 3 SQ9.1 - Install Mechanical Side Aisle Cable Tray | Remaining Tie-ins post Mech Side Aisle install | Not Started | 10/07/26 | 11/03/26 | 25.0 | 25.0 |
|
48.8 |
RPL10.INT.NS4.01520 |
RPL10.Interior.NS4 - Control Fault Domain 3 SQ9.1 - Install copper from GS.IDF to BMS and EPMS panels (UG from Center ID | Remaining Tie-ins post Mech Side Aisle install | Not Started | 10/07/26 | 11/03/26 | 25.0 | 25.0 |
|
57.5 |
RPL10.SSBC.BB.1700 |
RPL10.Ext.Build Back.SSB-Corr - LO #1 - MEPF Trim Out | Build Back Exterior Leave Out Wall #1 (Tent Area) | Not Started | 10/07/26 | 10/20/26 | 12.5 | 12.5 |
|
46.2 |
RPL10.W3B.FE.011251 |
RPL10.Conn EF1B<>NS4.CFD1 (P2-3) Pull Fiber Trunk (384F) [EF<>SSW] | EF1B<>NS4.1 (P2-3) [EF<>SSW] | Not Started | 10/07/26 | 10/07/26 | 1.2 | 1.2 |
|
50.0 |
RPL10.W3B.FE.011371 |
RPL10.Conn EF2B<>NS4.CFD1 (P1-4) Pull Fiber Trunk (384F) [EF<>SSW] | EF2B<>NS4.1 (P1-4) [EF<>SSW] | Not Started | 10/07/26 | 10/08/26 | 2.5 | 2.5 |
|
43.8 |
RPL10.W3B.FE.011916 |
RPL10.Conn EF2B<>NS2.CFD2 (P1-4) Install Fiber Trunk (288F) [EF<>JXSW] | EF2B<>NS2.5 (P1-4) [EF<>JXSW] | Not Started | 10/07/26 | 10/09/26 | 3.8 | 3.8 |
|
28.8 |
RPL10.W3B.FE.013206 |
RPL10.Conn EF1F<>NS2.CFD3 (P2-3) Test Fiber Trunk (384F) [EF<>SSW] | EF1F<>NS2.4 (P2-3) [EF<>SSW] | Not Started | 10/07/26 | 10/08/26 | 2.5 | 2.5 |
|
33.8 |
RPL10.WP3A.EF2B.1155 |
RPL10.Conn EF2B(OPE)<>EF2B(MBOX) Pull/Install/Test OSP Cabling (for RPL09) - P4 | EF2B<>EF2B | Not Started | 10/07/26 | 10/12/26 | 5.0 | 5.0 |
|
161.2 |
RPL10.WP3B.FE.02240 |
RPL10.Conn EF2B<>NS4.CFD1 (P1-4) Pull/Install/Test - WBS Summary | EF2B<>NS4.1 (P1-4) [EF<>SSW] | Not Started | 10/07/26 | 10/14/26 | 7.5 | 7.5 |
|
63.8 |
RPL10.WP3B.FE.02280 |
RPL10.Conn EF1B<>NS4.CFD1 (P2-3) Pull/Install/Test - WBS Summary | EF1B<>NS4.1 (P2-3) [EF<>SSW] | Not Started | 10/07/26 | 10/20/26 | 12.5 | 12.5 |
|
63.8 |
RPL10.WP4.018760 |
RPL10.Conn NS2.CFD4.48<>46-49 Install (A-End/Passive) Duplex Jumper (LC<>LC) [RSW<>FSW] | Install (A-End/Passive) Duplex Jumper [RSW<>FSW] | Not Started | 10/07/26 | 10/08/26 | 2.5 | 2.5 |
|
88.8 |
RPL10.WP4.06700 |
RPL10.Conn NS4.CFD1.48<>36-40 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] | Pull Duplex Jumper [RSW<>FSW] | Not Started | 10/07/26 | 10/09/26 | 3.8 | 3.8 |
|
182.5 |
RPL10.WP4.NS1.04140 |
RPL10.Conn NS1.CFD1 - Install ORv3 | OFE - Passive In-row Racks, Racks (ORv3Ns, MCRs) & PON | Not Started | 10/07/26 | 10/15/26 | 8.8 | 8.8 |
|
7.5 |
RPL10.WP4.NS1.04160 |
RPL10.Conn NS1.CFD1 - Deliver & Assemble - PON | OFE - Passive In-row Racks, Racks (ORv3Ns, MCRs) & PON | Not Started | 10/07/26 | 10/15/26 | 8.8 | 8.8 |
|
61.2 |
GCD.RPL10.4265 |
[RPL10] TC Ready: Production Cabling Pathways Complete [NS4 Rows 9-16] | TC Ready: Production Cabling - NS4 | Not Started | 10/08/26 | 10/08/26 | 0.0 | 0.0 |
|
50.0 |
RPL10.CX.NS1.01180 |
RPL10.CX.NS1 - L3/L4 - Control Fault Domain 2 | NS1 Control Fault Domain 2 | Not Started | 10/08/26 | 10/29/26 | 20.0 | 20.0 |
|
20.0 |
RPL10.CX.NS1.01200 |
RPL10.CX.NS1 - L3/L4 - Remaining Electrical Equipment (Fire Alarm, Security, Lighting) | NS1 ELECTRICAL | Not Started | 10/08/26 | 10/28/26 | 18.8 | 18.8 |
|
36.2 |
RPL10.EY.NS2.01390 |
RPL10.EY.NS2 - Install Remaning EY Paving | Hardscape and Landscape | Not Started | 10/08/26 | 10/14/26 | 6.2 | 6.2 |
|
87.5 |
RPL10.EY.NS2.01410 |
RPL10.EY.NS2 - Install Remaining Electrical Panels (3) | Build Back Exterior Leave Out Wall #2 (Tent Area) | Not Started | 10/08/26 | 10/14/26 | 6.2 | 6.2 |
|
25.0 |
RPL10.EY.NS2.01420 |
RPL10.EY.NS2 - Install Remaining UPS-CU (4) and CU (9) | Build Back Exterior Leave Out Wall #2 (Tent Area) | Not Started | 10/08/26 | 10/19/26 | 10.0 | 10.0 |
|
18.8 |
RPL10.INT.SSBC.01290 |
RPL10.Interior.SSB-Corridor - BoW - Install Cable Tray | Build Back Exterior Leave Out Wall #1 (Tent Area) | Not Started | 10/08/26 | 10/14/26 | 6.2 | 6.2 |
|
38.8 |
RPL10.INT.SSBC.01550 |
RPL10.Int.Build Back.SSB-Corr - LO #5 - Remaining NS2 L2 Checklist Completion | Build Back Interior Leave Out Wall #5 (NS2) | Not Started | 10/08/26 | 10/14/26 | 6.2 | 6.2 |
|
60.0 |
RPL10.ORV3.010240 |
OFE - Delivery ROJ: ORv3 for CFD NS2.1 (ROJ 10.22.26) (RVCD 11.05.26) | NS2 | Not Started | 10/08/26 | 10/28/26 | 18.8 | 18.8 |
|
-18.8 |
RPL10.SKN.NS12.01140 |
RPL10.SKIN.NS12 - Install Perm Doors | Glazing, Doors and Ext Devices | Not Started | 10/08/26 | 10/09/26 | 2.5 | 2.5 |
|
53.8 |
RPL10.SKN.SSB.01150 |
RPL10.SKIN.SSB - Install Perm Doors | Glazing, Doors and Ext Devices | Not Started | 10/08/26 | 10/09/26 | 2.5 | 2.5 |
|
53.8 |
RPL10.W3B.FE.011611 |
RPL10.Conn EF1F<>NS2.CFD2 (P2-3) Pull Fiber Trunk (384F) [EF<>SSW] | EF1F<>NS2.5 (P2-3) [EF<>SSW] | Not Started | 10/08/26 | 10/12/26 | 3.8 | 3.8 |
|
46.2 |
RPL10.W3B.FE.011651 |
RPL10.Conn EF1F<>NS4.CFD1 (P2-3) Pull Fiber Trunk (384F) [EF<>SSW] | EF1F<>NS4.1 (P2-3) [EF<>SSW] | Not Started | 10/08/26 | 10/08/26 | 1.2 | 1.2 |
|
51.2 |
RPL10.WP3B.FE.02260 |
RPL10.Conn EF1F<>NS4.CFD1 (P2-3) Pull/Install/Test - WBS Summary | EF1F<>NS4.1 (P2-3) [EF<>SSW] | Not Started | 10/08/26 | 10/22/26 | 13.8 | 13.8 |
|
63.8 |
RPL10.WP3B.FE.09140 |
RPL10.Conn EF1F<>NS2.CFD2 (P2-3) Pull/Install/Test - WBS Summary* | EF1F<>NS2.5 (P2-3) [EF<>SSW] | Not Started | 10/08/26 | 11/05/26 | 26.2 | 26.2 |
|
28.8 |
RPL10.WP4.011520 |
RPL10.Conn NS2.CFD6 Pull/Install In-Rack Fanout (LC<>MMC) [MA<>EB] | [MA<>EB] | Not Started | 10/08/26 | 10/09/26 | 2.5 | 2.5 |
|
52.5 |
RPL10.WP4.011540 |
RPL10.Conn NS1.CFD6 Pull/Install In-Rack Fanout (MPO<>MMC) [EB<>DR] | [EB<>DR] | Not Started | 10/08/26 | 10/09/26 | 2.5 | 2.5 |
|
60.0 |
RPL10.WP4.016920 |
RPL10.Conn NS1.CFD3.25 Install (A-End/Passive) Duplex Jumper (LC<>LC) [MA<>JXSW] | Install (A-End/Passive) Duplex Jumper [MA<>JXSW] | Not Started | 10/08/26 | 10/09/26 | 2.5 | 2.5 |
|
58.8 |
RPL10.WP4.017080 |
RPL10.Conn NS1.CFD3.48<>03-05 Install (A-End/Passive) Duplex Jumper (LC<>LC) [RSW<>FSW] | Install (A-End/Passive) Duplex Jumper [RSW<>FSW] | Not Started | 10/08/26 | 10/09/26 | 2.5 | 2.5 |
|
53.8 |
RPL10.WP4.030000 |
RPL10.Conn NS4.CFD2.48<>46-49 Prefab Duplex Jumper (LC<>LC) [RSW<>FSW] | Prefab | Not Started | 10/08/26 | 10/08/26 | 1.2 | 1.2 |
|
162.5 |
RPL10.WP4.030280 |
RPL10.Conn NS4.CFD4.48<>16-20 Prefab Duplex Jumper (LC<>LC) [RSW<>FSW] | Prefab | Not Started | 10/08/26 | 10/13/26 | 5.0 | 5.0 |
|
137.5 |
RPL10.WP4.031200 |
RPL10.Conn NS3.CFD2.48<>46-49 Prefab Duplex Jumper (LC<>LC) [RSW<>FSW] | Prefab | Not Started | 10/08/26 | 10/08/26 | 1.2 | 1.2 |
|
175.0 |
RPL10.WP4.032520 |
RPL10.Conn NS1.CFD2.34 Install (Z-End/Active) Duplex Jumper (LC<>LC) [MA<>JXSW] | Install Duplex Jumper [MA<>JXSW] | Not Started | 10/08/26 | 10/09/26 | 2.5 | 2.5 |
|
61.2 |
RPL10.WP4.033080 |
RPL10.Conn NS2.CFD3.30 Install (Z-End/Active) Duplex Jumper (LC<>LC) [MA<>JXSW] | Install Duplex Jumper [MA<>JXSW] | Not Started | 10/08/26 | 10/09/26 | 2.5 | 2.5 |
|
82.5 |
RPL10.WP4.06720 |
RPL10.Conn NS4.CFD1.48<>41-44 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] | Pull Duplex Jumper [RSW<>FSW] | Not Started | 10/08/26 | 10/09/26 | 2.5 | 2.5 |
|
185.0 |
RPL10.WP4.NS2.02780 |
RPL10.Conn NS2.CFD3 Network - WBS Summary | Network | Not Started | 10/08/26 | 12/17/26 | 60.0 | 60.0 |
|
15.0 |
RPL10.WP4.NS2.02800 |
RPL10.Conn NS2.CFD3 Network Suite [JXSW<>MA] Trunks | Pre ORv3 Rack | Not Started | 10/08/26 | 10/19/26 | 10.0 | 10.0 |
|
15.0 |
RPL10.WP4.NS2.03620 |
RPL10.Conn NS2.CFD1 Infrastructure - WBS Summary | Infrastructure | Not Started | 10/08/26 | 10/13/26 | 5.0 | 5.0 |
|
62.5 |
RPL10.WP4.NS2.03780 |
RPL10.Conn NS2.CFD1 Infrastructure | Infrastructure | Not Started | 10/08/26 | 10/13/26 | 5.0 | 5.0 |
|
62.5 |
RPL10.WP4.NS4.01060 |
RPL10.Conn NS4.CFD1 Infrastructure - WBS Summary | Infrastructure | Not Started | 10/08/26 | 10/21/26 | 12.5 | 12.5 |
|
72.5 |
RPL10.WP4.NS4.01140 |
RPL10.Conn NS4.CFD1 Infrastructure | Infrastructure | Not Started | 10/08/26 | 10/21/26 | 12.5 | 12.5 |
|
72.5 |
RPL10.CX.NS1.01210 |
RPL10.CX.NS1 - L3/L4 - Remaining Mechanical Equipment (CU/CRAH) | NS1 MECHANICAL | Not Started | 10/09/26 | 11/05/26 | 25.0 | 25.0 |
|
36.2 |
RPL10.INT.NS3.01340 |
RPL10.Conn NS3.CFD2 - Set Passive Racks for WP3B | Infrastructure | Not Started | 10/09/26 | 10/13/26 | 3.8 | 3.8 |
|
46.2 |
RPL10.INT.NS3.03000 |
RPL10.Conn NS3.CFD2 - Set Passive Racks for PON | Infrastructure | Not Started | 10/09/26 | 10/13/26 | 3.8 | 3.8 |
|
156.2 |
RPL10.INT.NS4.01640 |
RPL10.Interior.NS4 - Control Fault Domain 4 SQ10.1 - Install Mechanical Side Aisle Cable Tray | Remaining Tie-ins post Mech Side Aisle install | Not Started | 10/09/26 | 11/05/26 | 25.0 | 25.0 |
|
68.8 |
RPL10.INT.NS4.01660 |
RPL10.Interior.NS4 - Control Fault Domain 4 SQ10.1 - Install copper from GS.IDF to BMS and EPMS panels (UG from Center I | Remaining Tie-ins post Mech Side Aisle install | Not Started | 10/09/26 | 11/05/26 | 25.0 | 25.0 |
|
78.8 |
RPL10.INT.NS4.02760 |
RPL10.Interior.NS4 - OFE - Control Fault Domain 5 SQ11.1 (Mech Side Aisle) | OFE NS4 Control Fault Domain 5 | Not Started | 10/09/26 | 10/20/26 | 10.0 | 10.0 |
|
66.2 |
RPL10.OFCI.7260 |
OFCI - Delivery ROJ: FE Fiber for CFD NS3.5 (ROJ ) (RVCD ) | NS3 | Not Started | 10/09/26 | 10/29/26 | 18.8 | 18.8 |
|
82.5 |
RPL10.W3B.FE.011771 |
RPL10.Conn EF2F<>NS4.CFD1 (P1-4) Pull Fiber Trunk (384F) [EF<>SSW] | EF2F<>NS4.1 (P1-4) [EF<>SSW] | Not Started | 10/09/26 | 10/12/26 | 2.5 | 2.5 |
|
43.8 |
RPL10.W3B.FE.012101 |
RPL10.Conn EF2B<>NS1.CFD2 (P1-4) Install Fiber Trunk (384F) [EF<>SSW] | EF2B<>NS1.5 (P1-4) [EF<>SSW] | Not Started | 10/09/26 | 10/12/26 | 2.5 | 2.5 |
|
18.8 |
RPL10.W3B.FE.012171 |
RPL10.Conn EF2B<>NS4.CFD1 (P1-4) Install Fiber Trunk (384F) [EF<>SSW] | EF2B<>NS4.1 (P1-4) [EF<>SSW] | Not Started | 10/09/26 | 10/12/26 | 2.5 | 2.5 |
|
43.8 |
RPL10.W3B.FE.012696 |
RPL10.Conn EF2B<>NS1.CFD2 (P1-4) Test Fiber Trunk (288F) [EF<>JXSW] | EF2B<>NS1.5 (P1-4) [EF<>JXSW] | Not Started | 10/09/26 | 10/12/26 | 2.5 | 2.5 |
|
22.5 |
RPL10.WP3A.EF1B.1155 |
RPL10.Conn EF1B(OPE)<>EF2B(MBOX) Pull/Install/Test OSP Cabling (for RPL07) - P4 | EF1B<>EF2B | Not Started | 10/09/26 | 10/20/26 | 10.0 | 10.0 |
|
153.8 |
RPL10.WP3A.EF1F.1155 |
RPL10.Conn EF1F(OPE)<>EF2B(MBOX) Pull/Install/Test OSP Cabling (for RPL06) - P4 | EB1F<>EF2B | Not Started | 10/09/26 | 10/22/26 | 12.5 | 12.5 |
|
151.2 |
RPL10.WP3A.EF2B.1015 |
RPL10.Conn EF2B(LIU)<>EF1F(MBOX) Pull/Install/Test OSP Cabling (for RPL05) - P4 | EF2B<>EF1F | Not Started | 10/09/26 | 10/22/26 | 12.5 | 12.5 |
|
151.2 |
RPL10.WP3A.EF2B.1105 |
RPL10.Conn EF2B(OPE)<>EF1F(MBOX) Pull/Install/Test OSP Cabling (for RPL09) - P2 | EF2B<>EF2F | Not Started | 10/09/26 | 10/16/26 | 7.5 | 7.5 |
|
141.2 |
RPL10.WP3A.EF2F.1025 |
RPL10.Conn EF2F(OPE)<>EF1F(MBOX) Pull/Install/Test OSP Cabling (for RPL08) - P2 | EF2F<>EF1F | Not Started | 10/09/26 | 10/20/26 | 10.0 | 10.0 |
|
133.8 |
RPL10.WP3A.EF2F.1060 |
RPL10.Conn EF2F(OPE)<>EF1B(MBOX) Pull/Install/Test OSP Cabling (for RPL08) - P1 | EF2F<>EF1B | Not Started | 10/09/26 | 10/22/26 | 12.5 | 12.5 |
|
113.8 |
RPL10.WP3B.FE.02220 |
RPL10.Conn EF2F<>NS4.CFD1 (P1-4) Pull/Install/Test - WBS Summary | EF2F<>NS4.1 (P1-4) [EF<>SSW] | Not Started | 10/09/26 | 10/16/26 | 7.5 | 7.5 |
|
63.8 |
RPL10.WP4.018780 |
RPL10.Conn NS2.CFD3.25 Install (A-End/Passive) Duplex Jumper (LC<>LC) [MA<>JXSW] | Install (A-End/Passive) Duplex Jumper [MA<>JXSW] | Not Started | 10/09/26 | 10/12/26 | 2.5 | 2.5 |
|
68.8 |
RPL10.WP4.018940 |
RPL10.Conn NS2.CFD3.48<>03-05 Install (A-End/Passive) Duplex Jumper (LC<>LC) [RSW<>FSW] | Install (A-End/Passive) Duplex Jumper [RSW<>FSW] | Not Started | 10/09/26 | 10/12/26 | 2.5 | 2.5 |
|
63.8 |
RPL10.WP4.030920 |
RPL10.Conn NS3.CFD1.48<>26-30 Prefab Duplex Jumper (LC<>LC) [RSW<>FSW] | Prefab | Not Started | 10/09/26 | 10/14/26 | 5.0 | 5.0 |
|
158.8 |
RPL10.WP4.031260 |
RPL10.Conn NS3.CFD3.48<>11-15 Prefab Duplex Jumper (LC<>LC) [RSW<>FSW] | Prefab | Not Started | 10/09/26 | 10/15/26 | 6.2 | 6.2 |
|
142.5 |
RPL10.WP4.05080 |
RPL10.Conn NS3.CFD2.48<>03-05 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] | Pull Duplex Jumper [RSW<>FSW] | Not Started | 10/09/26 | 10/13/26 | 3.8 | 3.8 |
|
175.0 |
RPL10.WP4.05100 |
RPL10.Conn NS3.CFD2.48<>06-10 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] | Pull Duplex Jumper [RSW<>FSW] | Not Started | 10/09/26 | 10/13/26 | 3.8 | 3.8 |
|
176.2 |
RPL10.WP4.05120 |
RPL10.Conn NS3.CFD2.48<>11-15 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] | Pull Duplex Jumper [RSW<>FSW] | Not Started | 10/09/26 | 10/16/26 | 7.5 | 7.5 |
|
176.2 |
RPL10.WP4.06740 |
RPL10.Conn NS4.CFD1.48<>46-49 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] | Pull Duplex Jumper [RSW<>FSW] | Not Started | 10/09/26 | 10/09/26 | 1.2 | 1.2 |
|
187.5 |
RPL10.WP4.06760 |
RPL10.Conn NS4.CFD2.09 Pull Duplex Jumper (LC<>LC) [MA<>JXSW] | Pull Duplex Jumper [MA<>JXSW] | Not Started | 10/09/26 | 10/13/26 | 3.8 | 3.8 |
|
153.8 |
RPL10.WP4.06920 |
RPL10.Conn NS4.CFD2.48<>03-05 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] | Pull Duplex Jumper [RSW<>FSW] | Not Started | 10/09/26 | 10/13/26 | 3.8 | 3.8 |
|
162.5 |
RPL10.WP4.06940 |
RPL10.Conn NS4.CFD2.48<>06-10 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] | Pull Duplex Jumper [RSW<>FSW] | Not Started | 10/09/26 | 10/14/26 | 5.0 | 5.0 |
|
163.8 |
RPL10.WP4.06960 |
RPL10.Conn NS4.CFD2.48<>11-15 Pull Duplex Jumper (LC<>LC) [RSW<>FSW] | Pull Duplex Jumper [RSW<>FSW] | Not Started | 10/09/26 | 10/16/26 | 7.5 | 7.5 |
|
163.8 |
RPL10.WP4.NS4.01300 |
RPL10.Conn NS4.CFD2 Infrastructure - WBS Summary | Infrastructure | Not Started | 10/09/26 | 10/22/26 | 12.5 | 12.5 |
|
63.8 |
RPL10.WP4.NS4.01320 |
RPL10.Conn NS4.CFD2 Infrastructure | Infrastructure | Not Started | 10/09/26 | 10/22/26 | 12.5 | 12.5 |
|
63.8 |
GCD.RPL10.2612 |
L3/L4 Finish - NS1 Rows 17-24 | NS | Not Started | 10/12/26 | 10/12/26 | 0.0 | 0.0 |
|
58.8 |
GCD.RPL10.4765 |
L3/L4 Finish - NS2 Rows 17-24 | NS | Not Started | 10/12/26 | 10/12/26 | 0.0 | 0.0 |
|
70.0 |
RPL10.INT.NS3.01380 |
RPL10.Interior.NS3 - Control Fault Domain 2 SQ8.2 - Install copper from GS.IDF to BMS and EPMS panels | Remaining Tie-ins post Mech Side Aisle install | Not Started | 10/12/26 | 11/06/26 | 25.0 | 25.0 |
|
51.2 |
RPL10.INT.NS3.01450 |
RPL10.Interior.NS3 - Control Fault Domain 3 SQ9.2 - Pull BMS from panel to devices | Remaining Tie-ins post Mech Side Aisle install | Not Started | 10/12/26 | 11/06/26 | 25.0 | 25.0 |
|
66.2 |
RPL10.INT.NS3.01460 |
RPL10.Interior.NS3 - Control Fault Domain 3 SQ9.2 - Pull EPMS from panel to devices | Remaining Tie-ins post Mech Side Aisle install | Not Started | 10/12/26 | 11/06/26 | 25.0 | 25.0 |
|
66.2 |
RPL10.INT.NS3.01470 |
RPL10.Interior.NS3 - Control Fault Domain 3 SQ9.2 - Set UPS and Panel (2) and GS.IDF N32 | Remaining Tie-ins post Mech Side Aisle install | Not Started | 10/12/26 | 11/06/26 | 25.0 | 25.0 |
|
17.5 |
RPL10.W3B.FE.012131 |
RPL10.Conn EF2B<>NS2.CFD2 (P1-4) Install Fiber Trunk (384F) [EF<>SSW] | EF2B<>NS2.5 (P1-4) [EF<>SSW] | Not Started | 10/12/26 | 10/13/26 | 2.5 | 2.5 |
|
28.8 |
RPL10.W3B.FE.012716 |
RPL10.Conn EF2B<>NS2.CFD2 (P1-4) Test Fiber Trunk (288F) [EF<>JXSW] | EF2B<>NS2.5 (P1-4) [EF<>JXSW] | Not Started | 10/12/26 | 10/13/26 | 2.5 | 2.5 |
|
32.5 |
RPL10.WP4.011720 |
RPL10.Conn NS2.CFD6 Pull/Install In-Row Trunk (24F) [EB<>EB] | [EB<>EB] | Not Started | 10/12/26 | 10/15/26 | 5.0 | 5.0 |
|
52.5 |
RPL10.WP4.016940 |
RPL10.Conn NS1.CFD3.26 Install (A-End/Passive) Duplex Jumper (LC<>LC) [MA<>JXSW] | Install (A-End/Passive) Duplex Jumper [MA<>JXSW] | Not Started | 10/12/26 | 10/13/26 | 2.5 | 2.5 |
|
58.8 |
RPL10.WP4.017100 |
RPL10.Conn NS1.CFD3.48<>06-10 Install (A-End/Passive) Duplex Jumper (LC<>LC) [RSW<>FSW] | Install (A-End/Passive) Duplex Jumper [RSW<>FSW] | Not Started | 10/12/26 | 10/13/26 | 2.5 | 2.5 |
|
53.8 |
RPL10.WP4.030100 |
RPL10.Conn NS4.CFD3.48<>21-25 Prefab Duplex Jumper (LC<>LC) [RSW<>FSW] | Prefab | Not Started | 10/12/26 | 10/15/26 | 5.0 | 5.0 |
|
140.0 |