Schedule Viewer

Last schedule upload: D3-R25005-00-RPL10 — 8463 activities — 05/05/2026 09:13 AM CT
RPL10 - GC LIVE SCHEDULE - Data Date 20260426.xer · Uploaded May 05, 2026 02:13 PM · 8463 activities
Experimental Auto-populate checklist dates from schedule:
Clear
100
Activities Shown
0
Completed
0
In Progress
2
Critical
Activity ID Activity Name WBS Status Start Finish Dur (d) Rem (d) % Comp Float (d)
RPL10.WP4.027340 RPL10.Conn NS1.CFD6.48<>31-35 Prefab Duplex Jumper (LC<>LC) [RSW<>FSW] Prefab Not Started 06/19/26 06/23/26 3.8 3.8
0%
135.0
RPL10.WP4.027880 RPL10.Conn NS1.CFD3.48<>16-20 Prefab Duplex Jumper (LC<>LC) [RSW<>FSW] Prefab Not Started 06/19/26 06/24/26 5.0 5.0
0%
120.0
RPL10.WP4.028040 RPL10.Conn NS1.CFD2.48<>06-10 Prefab Duplex Jumper (LC<>LC) [RSW<>FSW] Prefab Not Started 06/19/26 06/23/26 3.8 3.8
0%
110.0
FR03.1320 FR03: PSI - NS1 - PCX H01 & H02 - 3rd Party Inspections FR03: House Power Skid Missing Panel Delay Not Started 06/22/26 06/23/26 2.5 2.5
0%
15.0
FR03.1440 FR03: PSI - NS2 - PCX H01 & H02 - 3rd Party Inspections FR03: House Power Skid Missing Panel Delay Not Started 06/22/26 06/23/26 2.5 2.5
0%
15.0
GCD.RPL10.6185 L3/L4 Start mCUP [1-4] - RPL10 mCup Not Started 06/22/26 06/22/26 0.0 0.0
0%
460.0
ICM.B10.2550 [NWB] L3/L4 Start mCUP [1-4] - RPL10 Commissioning Not Started 06/22/26 06/22/26 0.0 0.0
0%
460.0
RPL10.CX.MCUP.01050 RPL10.CX.mCup Loop 1 - L3/L4 - mCUP mCup Loop 1 (mCup #1,#3,#5,#7) Not Started 06/22/26 07/30/26 35.0 35.0
0%
30.0
RPL10.CX.MCUP.01190 RPL10.CX.mCup Loop 1 - L3/L4 - mCUP - Flush and Fill - mCup1 and Dry Coolers (MV Loop Needed) Fill and Flush Not Started 06/22/26 06/29/26 7.5 7.5
0%
51.2
RPL10.CX.MCUP.01210 RPL10.CX.mCup Loop 1 - L3/L4 - mCUP - Flush and Fill - mCup3 and Dry Coolers Fill and Flush Not Started 06/22/26 06/29/26 7.5 7.5
0%
51.2
RPL10.CX.MCUP.01230 RPL10.CX.mCup Loop 1 - L3/L4 - mCUP - Flush and Fill - mCup5 and Dry Coolers Fill and Flush Not Started 06/22/26 06/29/26 7.5 7.5
0%
51.2
RPL10.CX.MCUP.01250 RPL10.CX.mCup Loop 1 - L3/L4 - mCUP - Flush and Fill - mCup7 and Dry Coolers Fill and Flush Not Started 06/22/26 06/29/26 7.5 7.5
0%
51.2
RPL10.CX.NS1.01090 RPL10.CX.NS1 - L3/L4 - WBS Summary (Mechanical) NS1 MECHANICAL Not Started 06/22/26 11/18/26 131.2 131.2
0%
26.2
RPL10.CX.NS1.01260 RPL10.CX.NS1 - L3/L4 - Control Fault Domain 6 - FW Flush and Fill NS1 Control Fault Domain 6 Not Started 06/22/26 06/30/26 8.8 8.8
0%
26.2
RPL10.CX.NS2.01000 RPL10.CX.NS2 - L3, L4, IST - WBS Summary NS2 Not Started 06/22/26 03/19/27 232.5 232.5
0%
610.0
RPL10.CX.NS2.01090 RPL10.CX.NS2 - L3/L4 - WBS Summary (Mechanical) NS2 MECHANICAL Not Started 06/22/26 12/11/26 150.0 150.0
0%
18.8
RPL10.CX.NS2.01260 RPL10.CX.NS2 - L3/L4 - Control Fault Domain 6 - FW Flush and Fill NS2 Control Fault Domain 6 Not Started 06/22/26 06/30/26 8.8 8.8
0%
26.2
RPL10.INT.EF1.01230 RPL10.Interior.EF1 - North CRAH Gallery - Leak Detection / Heat Trace North CRAH Gallery Not Started 06/22/26 06/26/26 6.2 6.2
0%
92.5
RPL10.INT.EF1.01630 RPL10.Interior.EF1 - South CRAH Gallery - Piping Tie-ins FW (In Gallery #3 CRAH Units) South CRAH Gallery Not Started 06/22/26 07/02/26 11.2 11.2
0%
87.5
RPL10.INT.EF2.01300 RPL10.Interior.EF2 - North CRAH Gallery - Pull EPMS / BMS from panel to devices North CRAH Gallery Not Started 06/22/26 06/26/26 6.2 6.2
0%
110.0
RPL10.INT.EF2.01310 RPL10.Interior.EF2 - North CRAH Gallery - Fire Life Safety North CRAH Gallery Not Started 06/22/26 06/26/26 6.2 6.2
0%
177.5
RPL10.INT.EF2.01320 RPL10.Interior.EF2 - North CRAH Gallery - Install copper from GS.IDF to BMS and EPMS panels North CRAH Gallery Not Started 06/22/26 06/26/26 6.2 6.2
0%
110.0
RPL10.INT.EF2.01330 RPL10.Interior.EF2 - South CRAH Gallery - Pull EPMS / BMS from panel to devices South CRAH Gallery Not Started 06/22/26 06/26/26 6.2 6.2
0%
110.0
RPL10.INT.EF2.01340 RPL10.Interior.EF2 - South CRAH Gallery - Fire Life Safety South CRAH Gallery Not Started 06/22/26 06/26/26 6.2 6.2
0%
177.5
RPL10.INT.EF2.01350 RPL10.Interior.EF2 - South CRAH Gallery - Install copper from GS.IDF to BMS and EPMS panels South CRAH Gallery Not Started 06/22/26 06/26/26 6.2 6.2
0%
110.0
RPL10.INT.EF2.01520 RPL10.Interior.EF2 - EF2 West - Pull EPMS / BMS from panel to devices West EF-2 Not Started 06/22/26 06/26/26 6.2 6.2
0%
110.0
RPL10.INT.EF2.01530 RPL10.Interior.EF2 - EF2 West - Install copper from GS.IDF to BMS and EPMS panels West EF-2 Not Started 06/22/26 06/26/26 6.2 6.2
0%
110.0
RPL10.INT.EF2.01540 RPL10.Interior.EF2 - EF2 West - Fire Life Safety West EF-2 Not Started 06/22/26 06/30/26 8.8 8.8
0%
175.0
RPL10.INT.NS1.01730 RPL10.Interior.NS1 - Control Fault Domain 3 SQ4.1 - Install Mechanical Side Aisle Cable Tray Remaining Tie-ins post Mech Side Aisle install Not Started 06/22/26 07/20/26 25.0 25.0
0%
51.2
RPL10.INT.NS1.01760 RPL10.Interior.NS1 - Control Fault Domain 3 SQ4.1 - Install copper from GS.IDF to BMS and EPMS panels (UG from Center ID Remaining Tie-ins post Mech Side Aisle install Not Started 06/22/26 07/20/26 25.0 25.0
0%
33.8
RPL10.INT.NS3.01530 RPL10.Interior.NS3 - Control Fault Domain 3 SQ9.2 - Install LV Side Aisle Cable Tray LV Side Tie-ins Not Started 06/22/26 06/25/26 5.0 5.0
0%
145.0
RPL10.PR.PR.01030 ENS Rooms Required for Provisioning Start (ERAD room, Spoke Parts, Spoke Tech, ENS High Value Storage) Connectivity Milestones Not Started 06/22/26 06/22/26 0.0 0.0
0%
178.8
RPL10.W3B.FE.011161 RPL10.Conn EF1B<>NS1.CFD6 (P2-3) Pull Fiber Trunk (384F) [EF<>SSW] EF1B<>NS1.1 (P2-3) [EF<>SSW] Not Started 06/22/26 06/24/26 3.8 3.8
0%
26.2
RPL10.W3B.FE.011191 RPL10.Conn EF1B<>NS2.CFD6 (P2-3) Pull Fiber Trunk (384F) [EF<>SSW] EF1B<>NS2.1 (P2-3) [EF<>SSW] Not Started 06/22/26 06/25/26 5.0 5.0
0%
35.0
RPL10.W3B.FE.011281 RPL10.Conn EF2B<>NS1.CFD6 (P1-4) Pull Fiber Trunk (384F) [EF<>SSW] EF2B<>NS1.1 (P1-4) [EF<>SSW] Not Started 06/22/26 06/24/26 3.8 3.8
0%
18.8
RPL10.W3B.FE.011311 RPL10.Conn EF2B<>NS2.CFD6 (P1-4) Pull Fiber Trunk (384F) [EF<>SSW] EF2B<>NS2.1 (P1-4) [EF<>SSW] Not Started 06/22/26 06/24/26 3.8 3.8
0%
32.5
RPL10.WP2.GSIDF.1220 RPL10.Conn IDF Huts - (GSMDF to GSIDF) NS1 N12 WBS Summary GSIDFN12 Not Started 06/22/26 07/23/26 28.8 28.8
0%
431.2
RPL10.WP2.GSIDF.1240 RPL10.Conn GSIDFN12 Install Infrastructure (Racks, Waterfalls etc.) Infrastructure Not Started 06/22/26 06/26/26 6.2 6.2
0%
183.8
RPL10.WP3B.FE.01020 RPL10.Conn NS1.CFD6 (FE) ISP Cabling - WBS Summary FENW (Front End Network) Not Started 06/22/26 07/10/26 17.5 17.5
0%
41.2
RPL10.WP3B.FE.01115 RPL10.Conn EF2B<>NS1.CFD6 (P1-4) Pull/Install/Test - WBS Summary EF2B<>NS1.1 (P1-4) [EF<>SSW] Not Started 06/22/26 06/30/26 8.8 8.8
0%
42.5
RPL10.WP3B.FE.01125 RPL10.Conn EF1B<>NS1.CFD6 (P2-3) Pull/Install/Test - WBS Summary EF1B<>NS1.1 (P2-3) [EF<>SSW] Not Started 06/22/26 07/08/26 15.0 15.0
0%
41.2
RPL10.WP3B.FE.02000 RPL10.Conn NS2.CFD6 (FE) ISP Cabling - WBS Summary FENW (Front End Network) Not Started 06/22/26 07/10/26 17.5 17.5
0%
52.5
RPL10.WP3B.FE.02080 RPL10.Conn EF2B<>NS2.CFD6 (P1-4) Pull/Install/Test - WBS Summary EF2B<>NS2.1 (P1-4) [EF<>SSW] Not Started 06/22/26 06/30/26 8.8 8.8
0%
53.8
RPL10.WP3B.FE.02120 RPL10.Conn EF1B<>NS2.CFD6 (P2-3) Pull/Install/Test - WBS Summary EF1B<>NS2.1 (P2-3) [EF<>SSW] Not Started 06/22/26 07/08/26 15.0 15.0
0%
52.5
RPL10.WP4.028880 RPL10.Conn NS2.CFD4.48<>16-20 Prefab Duplex Jumper (LC<>LC) [RSW<>FSW] Prefab Not Started 06/22/26 06/25/26 5.0 5.0
0%
130.0
RPL10.WP4.NS1.01120 RPL10.Conn NS1.CFD6 Network Suite [JXSW<>MA] Multi Drop Cable Pre ORv3 Rack Not Started 06/22/26 06/24/26 3.8 3.8
0%
70.0
RPL10.EY.NS4.01200 RPL10.EY.NS4 - HAC Prefab prior to install Tent and Temp Conditions Not Started 06/23/26 07/07/26 12.5 12.5
0%
68.8
RPL10.INT.ENDC.01290 RPL10.Interior.End-Corridor - BoW - Install Battery Balance of Walls & Overhead Not Started 06/23/26 07/07/26 12.5 12.5
0%
183.8
RPL10.INT.ENDC.1620 RPL10.Interior.End-Corridor - BoW - Security Trim Out Balance of Walls & Overhead Not Started 06/23/26 07/02/26 10.0 10.0
0%
198.8
RPL10.INT.ENDC.1640 RPL10.Interior.End-Corridor - BoW - Duct Drops / Trim out Balance of Walls & Overhead Not Started 06/23/26 06/29/26 6.2 6.2
0%
198.8
RPL10.INT.ENDC.1660 RPL10.Interior.End-Corridor - BoW - Final Paint Balance of Walls & Overhead Not Started 06/23/26 07/02/26 10.0 10.0
0%
201.2
RPL10.INT.NS1.02660 RPL10.Interior.NS1 - OFE - Control Fault Domain 2 SQ5.1 (HAC) OFE NS1 Control Fault Domain 2 Not Started 06/23/26 07/14/26 18.8 18.8
0%
-5.0
RPL10.INT.NS2.01500 RPL10.Interior.NS2 - Control Fault Domain 4 SQ3.2 - Install Mechanical Side Aisle Cable Tray Remaining Tie-ins post Mech Side Aisle install Not Started 06/23/26 07/21/26 25.0 25.0
0%
36.2
RPL10.INT.NS2.01530 RPL10.Interior.NS2 - Control Fault Domain 4 SQ3.2 - Install copper from GS.IDF to BMS and EPMS panels (UG from Center ID Remaining Tie-ins post Mech Side Aisle install Not Started 06/23/26 07/21/26 25.0 25.0
0%
16.2
RPL10.INT.NS3.01550 RPL10.Interior.NS3 - Control Fault Domain 4 SQ10.2 - Install Duct (LV Side) LV Side Tie-ins Not Started 06/23/26 06/26/26 5.0 5.0
0%
132.5
RPL10.INT.NS3.01580 RPL10.Interior.NS3 - Tie-ins - Control Fault Domain 4 SQ10.2 - WBS Summary Tie-Ins NS3 Control Fault Domain 4 Not Started 06/23/26 12/09/26 146.2 146.2
0%
72.5
RPL10.INT.NS4.01830 RPL10.Interior.NS4 - Control Fault Domain 6 SQ12.1 - Install Duct (LV Side) LV Side Tie-ins Not Started 06/23/26 06/26/26 5.0 5.0
0%
193.8
RPL10.INT.NS4.01860 RPL10.Interior.NS4 - Tie-ins - Control Fault Domain 6 SQ12.1 - WBS Summary Tie-Ins NS4 Control Fault Domain 6 Not Started 06/23/26 12/28/26 161.2 161.2
0%
82.5
RPL10.SKN.NS12.01030 RPL10.SKIN.NS12 - Install Awning over Doors Glazing, Doors and Ext Devices Not Started 06/23/26 06/29/26 6.2 6.2
0%
125.0
RPL10.SKN.SSB.01120 RPL10.SKIN.SSB - Install Scupper and Downspouts Glazing, Doors and Ext Devices Not Started 06/23/26 06/29/26 6.2 6.2
0%
132.5
RPL10.WP2.GSIDF.2400 RPL10.Conn GSIDFNX05 Install & Test Network (FIM) Network Not Started 06/23/26 06/25/26 3.8 3.8
0%
196.2
RPL10.WP2.GSIDF.2760 RPL10.Conn GSIDFNX10 Install Cabling (Pull, Splice & terminate) Cabling Not Started 06/23/26 07/14/26 18.8 18.8
0%
177.5
RPL10.WP2.GSIDF.3360 RPL10.Conn GSIDFNX05 Install Copper, WAPs, Security Camera & Access Control Cabling Not Started 06/23/26 06/25/26 3.8 3.8
0%
455.0
RPL10.WP4.01280 RPL10.Conn NS1.CFD5.12 Pull Duplex Jumper (LC<>LC) [MA<>JXSW] Pull Duplex Jumper [MA<>JXSW] Not Started 06/23/26 06/25/26 3.8 3.8
0%
146.2
RPL10.WP4.027560 RPL10.Conn NS1.CFD5.48<>36-40 Prefab Duplex Jumper (LC<>LC) [RSW<>FSW] Prefab Not Started 06/23/26 06/25/26 3.8 3.8
0%
136.2
RPL10.WP4.027760 RPL10.Conn NS1.CFD4.48<>36-40 Prefab Duplex Jumper (LC<>LC) [RSW<>FSW] Prefab Not Started 06/23/26 06/25/26 3.8 3.8
0%
136.2
RPL10.WP4.028560 RPL10.Conn NS2.CFD6.48<>36-40 Prefab Duplex Jumper (LC<>LC) [RSW<>FSW] Prefab Not Started 06/23/26 06/25/26 3.8 3.8
0%
147.5
RPL10.WP4.028760 RPL10.Conn NS2.CFD5.48<>36-40 Prefab Duplex Jumper (LC<>LC) [RSW<>FSW] Prefab Not Started 06/23/26 06/25/26 3.8 3.8
0%
147.5
RPL10.WP4.NS2.01380 RPL10.Conn NS2.CFD6 Infrastructure - WBS Summary Infrastructure Not Started 06/23/26 06/26/26 5.0 5.0
0%
71.2
RPL10.WP4.NS2.01400 RPL10.Conn NS2.CFD6 Infrastructure Infrastructure Not Started 06/23/26 06/26/26 5.0 5.0
0%
71.2
FR03.1340 FR03: PSI - NS1 - PCX H01 & H02 - Issue Resolution FR03: House Power Skid Missing Panel Delay Not Started 06/24/26 06/25/26 2.5 2.5
0%
15.0
FR03.1460 FR03: PSI - NS2 - PCX H01 & H02 - Issue Resolution FR03: House Power Skid Missing Panel Delay Not Started 06/24/26 06/25/26 2.5 2.5
0%
15.0
RPL.10.D.X35X0.XR Substation Perm Power Cutover - RPL10 NS & mCUPs (Potential for remaining provisioning) Power (XREFs) Not Started 06/24/26 06/24/26 0.0 0.0
0%
301.2
RPL.GF.D.N0270.XR Fiber Pulls, Test & Term All Prod EF to EF Complete RPL 10 to RPL8 Connectivity (XREFs) Not Started 06/24/26 06/24/26 0.0 0.0
0%
202.5
RPL.GF.D.N0300.XR Fiber Pulls, Test & Term All Prod EF to EF Complete RPL 10 to AI3 Connectivity (XREFs) Not Started 06/24/26 06/24/26 0.0 0.0
0%
145.0
RPL10.EY.NS4.01270 RPL10.EY.NS4 - Install GS.IDF Hut (1x GS.IDF) NX04 (05.29.26) OFE Not Started 06/24/26 06/30/26 6.2 6.2
0%
101.2
RPL10.INT.NS2.02645 RPL10.Interior.NS2 - OFE - Control Fault Domain 3 SQ4.2 (HAC) OFE NS2 Control Fault Domain 3 Not Started 06/24/26 07/15/26 18.8 18.8
0%
-18.8
RPL10.WP4.027360 RPL10.Conn NS1.CFD6.48<>36-40 Prefab Duplex Jumper (LC<>LC) [RSW<>FSW] Prefab Not Started 06/24/26 06/26/26 3.8 3.8
0%
135.0
RPL10.WP4.028060 RPL10.Conn NS1.CFD2.48<>11-15 Prefab Duplex Jumper (LC<>LC) [RSW<>FSW] Prefab Not Started 06/24/26 06/30/26 6.2 6.2
0%
110.0
RPL.10.D.X33X4.XR Pull and Term MV Skids - RPL10 NS4 Loop 1 & 2 Power (XREFs) Not Started 06/25/26 06/25/26 0.0 0.0
0%
125.0
RPL10.Conn.MS.01510 Wifi Ready - SSB Connectivity Milestones Not Started 06/25/26 06/25/26 0.0 0.0
0%
455.0
RPL10.INT.EF1.01580 RPL10.Interior.EF1 - Final Clean Tie-Ins Not Started 06/25/26 06/30/26 5.0 5.0
0%
168.8
RPL10.INT.NS1.01810 RPL10.Interior.NS1 - Control Fault Domain 2 SQ5.1 - Pull BMS from panel to devices Remaining Tie-ins post Mech Side Aisle install Not Started 06/25/26 07/23/26 25.0 25.0
0%
40.0
RPL10.INT.NS1.01820 RPL10.Interior.NS1 - Control Fault Domain 2 SQ5.1 - Pull EPMS from panel to devices Remaining Tie-ins post Mech Side Aisle install Not Started 06/25/26 07/23/26 25.0 25.0
0%
40.0
RPL10.INT.NS1.01830 RPL10.Interior.NS1 - Control Fault Domain 2 SQ5.1 - Set UPS and Panel (2) Remaining Tie-ins post Mech Side Aisle install Not Started 06/25/26 07/23/26 25.0 25.0
0%
33.8
RPL10.INT.NS3.01630 RPL10.Interior.NS3 - OFE - Control Fault Domain 5 SQ11.2 (LV Side Aisle, HAC, Mech Side Aisle) OFE NS3 Control Fault Domain 5 Not Started 06/25/26 11/12/26 122.5 122.5
0%
40.0
RPL10.INT.NS3.01650 RPL10.Interior.NS3 - Control Fault Domain 4 SQ10.2 - Install LV Side Aisle HAC Busway LV Side Tie-ins Not Started 06/25/26 06/30/26 5.0 5.0
0%
165.0
RPL10.INT.NS3.02740 RPL10.Interior.NS3 - OFE - Control Fault Domain 5 SQ11.2 (LV Side Aisle) OFE NS3 Control Fault Domain 5 Not Started 06/25/26 06/30/26 5.0 5.0
0%
147.5
RPL10.INT.NS4.01920 RPL10.Interior.NS4 - Control Fault Domain 6 SQ12.1 - Install LV Side Aisle HAC Busway LV Side Tie-ins Not Started 06/25/26 06/30/26 5.0 5.0
0%
223.8
RPL10.INT.SSB.02620 RPL10.Interior.SSB - BoW - ACT - Install ACT Tiles Balance of Walls and OverHead Not Started 06/25/26 07/06/26 8.8 8.8
0%
147.5
RPL10.W3B.FE.011561 RPL10.Conn EF1F<>NS1.CFD6 (P2-3) Pull Fiber Trunk (384F) [EF<>SSW] EF1F<>NS1.1 (P2-3) [EF<>SSW] Not Started 06/25/26 06/29/26 3.8 3.8
0%
26.2
RPL10.W3B.FE.011681 RPL10.Conn EF2F<>NS1.CFD6 (P1-4) Pull Fiber Trunk (384F) [EF<>SSW] EF2F<>NS1.1 (P1-4) [EF<>SSW] Not Started 06/25/26 06/29/26 3.8 3.8
0%
18.8
RPL10.W3B.FE.011711 RPL10.Conn EF2F<>NS2.CFD6 (P1-4) Pull Fiber Trunk (384F) [EF<>SSW] EF2F<>NS2.1 (P1-4) [EF<>SSW] Not Started 06/25/26 06/29/26 3.8 3.8
0%
32.5
RPL10.W3B.FE.012081 RPL10.Conn EF2B<>NS1.CFD6 (P1-4) Install Fiber Trunk (384F) [EF<>SSW] EF2B<>NS1.1 (P1-4) [EF<>SSW] Not Started 06/25/26 06/26/26 2.5 2.5
0%
22.5
RPL10.W3B.FE.012111 RPL10.Conn EF2B<>NS2.CFD6 (P1-4) Install Fiber Trunk (384F) [EF<>SSW] EF2B<>NS2.1 (P1-4) [EF<>SSW] Not Started 06/25/26 06/26/26 2.5 2.5
0%
33.8
RPL10.WP3B.FE.01110 RPL10.Conn EF2F<>NS1.CFD6 (P1-4) Pull/Install/Test - WBS Summary EF2F<>NS1.1 (P1-4) [EF<>SSW] Not Started 06/25/26 07/06/26 8.8 8.8
0%
41.2
RPL10.WP3B.FE.01120 RPL10.Conn EF1F<>NS1.CFD6 (P2-3) Pull/Install/Test - WBS Summary EF1F<>NS1.1 (P2-3) [EF<>SSW] Not Started 06/25/26 07/10/26 13.8 13.8
0%
41.2
RPL10.WP3B.FE.02060 RPL10.Conn EF2F<>NS2.CFD6 (P1-4) Pull/Install/Test - WBS Summary EF2F<>NS2.1 (P1-4) [EF<>SSW] Not Started 06/25/26 07/06/26 8.8 8.8
0%
52.5
RPL10.WP4.027900 RPL10.Conn NS1.CFD3.48<>21-25 Prefab Duplex Jumper (LC<>LC) [RSW<>FSW] Prefab Not Started 06/25/26 06/30/26 5.0 5.0
0%
120.0
GCD.RPL10.3529 [RPL10] TC Ready: Production Cabling Pathways Complete [NS1 Rows 17-24] TC Ready: Production Cabling - NS1 Not Started 06/26/26 06/26/26 0.0 0.0
0%
47.5