Schedule Viewer
Last schedule upload: D3-R25005-00-RPL10 — 8463 activities — 05/05/2026 09:13 AM CT
RPL10 - GC LIVE SCHEDULE - Data Date 20260426.xer
· Uploaded May 05, 2026 02:13 PM
· 8463 activities
Experimental
Auto-populate checklist dates from schedule:
100
Activities Shown
95
Completed
5
In Progress
95
Critical
| Activity ID | Activity Name | WBS | Status | Start | Finish | Dur (d) | Rem (d) | % Comp | Float (d) |
|---|---|---|---|---|---|---|---|---|---|
RPL10.MR.1260 |
RPL10.MR - Mobilization Complete | Make Ready | Complete | 08/25/25 | 08/25/25 | 0.0 | 0.0 |
|
0.0 |
RPL10.SUB.1000 |
RPL10.SubStructure.BLDG - Install Deep/Foundations/Gradebeams/Stemwalls/UG Utilities - WBS Summary | SubStructure | Complete | 08/25/25 | 11/19/25 | 77.5 | 0.0 |
|
0.0 |
RPL10.SUB.SSB.01010 |
RPL10.SubStructure.SSB - Install Deep/Foundations/Gradebeams/Stemwalls - WBS Summary | Foundations | Complete | 08/25/25 | 10/14/25 | 40.0 | 0.0 |
|
0.0 |
RPL10.SUB.SSB.01020 |
RPL10.SubStructure.SSB - Install Deep/Foundations/Gradebeams/Stemwalls/UG Utilities - WBS Summary | SSB | Complete | 08/25/25 | 10/14/25 | 45.0 | 0.0 |
|
0.0 |
RPL10.SUB.SSB.01160 |
RPL10.SubStructure.SSB - Install Drilled Piers - Grid lines 10-42/10-30 -Before Impact - Part 1 | Foundations | Complete | 08/25/25 | 08/28/25 | 5.0 | 0.0 |
|
0.0 |
JCL.C.1080 |
RPL10 - Cost Risk LOE-5 Substructure | Cost LOEs | Active | 08/27/25 | 12/16/26 | 5.0 | 202.5 |
|
90.0 |
JCL.C.1200 |
RPL10 - Cost Risk LOE-11 HVAC | Cost LOEs | Active | 08/27/25 | 01/29/27 | 0.0 | 238.8 |
|
73.8 |
RPL10.SUB.NS12.01020 |
RPL10.SubStructure.NS12 - Install Deep/Foundations/Gradebeams/Stemwalls/UG Utilities - WBS Summary | NS1 & NS2 | Complete | 08/27/25 | 10/28/25 | 51.2 | 0.0 |
|
0.0 |
RPL10.SUB.NS12.01070 |
RPL10.SubStructure.NS12 - Install UG Utilities - WBS Summary | Underground | Complete | 08/27/25 | 10/28/25 | 51.2 | 0.0 |
|
0.0 |
RPL10.SUB.NS12.01120 |
RPL10.SubStructure.NS12 - Install UG Utilities - Building Generator Duct Bank (East)-Before Impact - Part 1 | Underground | Complete | 08/27/25 | 08/28/25 | 8.8 | 0.0 |
|
0.0 |
RPL10.SUB.NS12.01140 |
RPL10.SubStructure.NS12 - Install UG Utilities - Building Generator Duct Bank (West)-Before Impact - Part 1 | Underground | Complete | 08/27/25 | 08/28/25 | 8.8 | 0.0 |
|
0.0 |
RPL10.SUB.SSB.01050 |
RPL10.SubStructure.SSB - Install UG Utilities - Plumbing/Testing/Backfill-Before Impact-Part 1 | Underground | Complete | 08/27/25 | 08/28/25 | 20.0 | 0.0 |
|
0.0 |
RPL10.SUB.SSB.01060 |
RPL10.SubStructure.SSB - Install UG Utilities - WBS Summary | Underground | Complete | 08/27/25 | 10/14/25 | 40.0 | 0.0 |
|
0.0 |
RPL10.SUB.SSB.01200 |
RPL10.SubStructure.SSB - Piers Protection Concrete Capping-Before Impact - Part 1 | Foundations | Complete | 08/27/25 | 08/28/25 | 5.0 | 0.0 |
|
0.0 |
RPL10.SUB.SSB.01180 |
RPL10.SubStructure.SSB - Install Foundations/Anchor Bolts and Gradebeams - Grid lines 10-42/10-30-Before Impact-Part 1 | Foundations | Complete | 08/28/25 | 08/28/25 | 16.2 | 0.0 |
|
0.0 |
JCL.C.1220 |
RPL10 - Cost Risk LOE-12 Electrical | Cost LOEs | Active | 08/29/25 | 01/29/27 | 0.0 | 238.8 |
|
73.8 |
JCL.C.1240 |
RPL10 - Cost Risk LOE-13 Auxiliary Systems | Cost LOEs | Active | 08/29/25 | 01/29/27 | 0.0 | 238.8 |
|
73.8 |
NW.1940 |
Weather Event #1 - 08/29/25 | Project Impacts | Complete | 08/29/25 | 08/29/25 | 5.0 | 0.0 |
|
0.0 |
RPL10.SUB.NS12.01000 |
RPL10.SubStructure.NS12 - Install Drilled Piers - Grid lines 10-30/10-20 - Before Impact - Part 1 | Foundations | Complete | 08/29/25 | 08/29/25 | 5.0 | 0.0 |
|
0.0 |
RPL10.SUB.NS12.01010 |
RPL10.SubStructure.NS12 - Install Deep/Foundations/Gradebeams/Stemwalls - WBS Summary | Foundations | Complete | 08/29/25 | 10/17/25 | 41.2 | 0.0 |
|
0.0 |
RPL10.SUB.SSB.01090 |
RPL10.SubStructure.SSB - Install UG Utilities - Electrical/Inspection & Tie-ins (Outside to Inside) -Before Impact-Part1 | Underground | Complete | 08/29/25 | 08/29/25 | 16.2 | 0.0 |
|
0.0 |
PRE.FA.1220 |
Waterproofing / Caulking / Expansion Joints - Final Agreement | Trade Partner Final Agreement | Complete | 09/02/25 | 09/02/25 | 0.0 | 0.0 |
|
0.0 |
PRE.TPA.1280 |
Kitchen Equipment - Award and Issue Subcontract | DPR issue Trade Parter Agreements | Complete | 09/02/25 | 11/18/25 | 72.5 | 0.0 |
|
0.0 |
RPL10.CFCI.3830 |
RPL10 - Prep / Submit for Review - Building Controls | (CFCI) Div. 23 - Building Controls | Complete | 09/02/25 | 11/03/25 | 25.0 | 0.0 |
|
0.0 |
RPL10.CFCI.6150 |
RPL10- Submittal Rvw/App'l - CMU - Storm Shelter | (CFCI) Div. 04 - Concrete Masonry Units | Complete | 09/02/25 | 09/19/25 | 3.8 | 0.0 |
|
0.0 |
RPL10.SUB.EF12.01000 |
RPL10.SubStructure.EF12 - Install Drilled Piers - Grid lines 10-20/10-10 | Foundations | Complete | 09/02/25 | 09/03/25 | 3.8 | 0.0 |
|
0.0 |
RPL10.SUB.EF12.01010 |
RPL10.SubStructure.EF12 - Deep/Foundations/Gradebeams/Stemwalls - WBS Summary | Foundations | Complete | 09/02/25 | 10/27/25 | 48.8 | 0.0 |
|
0.0 |
RPL10.SUB.EF12.01020 |
RPL10.SubStructure.EF12 - Install Deep/Foundations/Gradebeams/Stemwalls/UG Utilities - WBS Summary | EF1 & EF2 | Complete | 09/02/25 | 11/07/25 | 61.2 | 0.0 |
|
0.0 |
RPL10.SUB.NS12.01130 |
RPL10.SubStructure.NS12 - Piers Protection Concrete Capping | Foundations | Complete | 09/02/25 | 09/08/25 | 5.0 | 0.0 |
|
0.0 |
RPL10.SUB.NS12.01160 |
RPL10.SubStructure.NS12 - Install Drilled Piers - Grid lines 10-30/10-20 - After Impact - Part 2 | Foundations | Complete | 09/02/25 | 09/03/25 | 5.0 | 0.0 |
|
0.0 |
RPL10.SUB.NS12.01180 |
RPL10.SubStructure.NS12 - Install UG Utilities - Building Generator Duct Bank (East)-After Impact - Part 2 | Underground | Complete | 09/02/25 | 09/23/25 | 8.8 | 0.0 |
|
0.0 |
RPL10.SUB.NS12.01200 |
RPL10.SubStructure.NS12 - Install UG Utilities - Building Generator Duct Bank (West)-After Impact - Part 2 | Underground | Complete | 09/02/25 | 09/17/25 | 8.8 | 0.0 |
|
0.0 |
RPL10.SUB.SSB.01000 |
RPL10.SubStructure.SSB - Install Drilled Piers - Grid lines 10-42/10-30 - After Impact - Part 2 | Foundations | Complete | 09/02/25 | 09/02/25 | 5.0 | 0.0 |
|
0.0 |
RPL10.SUB.SSB.01040 |
RPL10.SubStructure.SSB - Install Foundations/Anchor Bolts and Gradebeams - Grid lines 10-42/10-30-After Impact-Part 2 | Foundations | Complete | 09/02/25 | 10/03/25 | 16.2 | 0.0 |
|
0.0 |
RPL10.SUB.SSB.01140 |
RPL10.SubStructure.SSB - Piers Protection Concrete Capping-After Impact - Part 2 | Foundations | Complete | 09/02/25 | 09/10/25 | 5.0 | 0.0 |
|
0.0 |
RPL10.VDC.4240 |
RPL10.T1 (SSB to Center EF) - BIM Prepare & Submit Shops - Priority 1 | Priority 1 - SSB to EF | Complete | 09/02/25 | 10/03/25 | 6.2 | 0.0 |
|
0.0 |
RPL10.VDC.4260 |
RPL10.T1 (SSB to Center EF) - BIM Review & Approve Shops - Priority 1 | Priority 1 - SSB to EF | Complete | 09/02/25 | 10/21/25 | 8.8 | 0.0 |
|
0.0 |
RPL10.VDC.4280 |
RPL10.T1 (SSB to Center EF) - BIM Model/Shops - Priority 1 Final Review (Page Turn) | Priority 1 - SSB to EF | Complete | 09/02/25 | 10/21/25 | 18.8 | 0.0 |
|
0.0 |
RPL10.VDC.4380 |
RPL10.T1 (Misc. Steel) - BIM Model & Coordination - Priority 3 | Priority 3 - Misc Steel | Complete | 09/02/25 | 10/03/25 | 17.5 | 0.0 |
|
0.0 |
RPL10.VDC.3860 |
RPL10.T0 (SSB to Center EF) - BIM Model/Shops - Priority 2 Final Review (Page Turn) | Priority 2 Priority 2 SSB to Center of EF | Complete | 09/03/25 | 09/14/25 | 11.2 | 0.0 |
|
0.0 |
RPL10.VDC.4540 |
RPL10.BIM TIER 2 - 4 - Clash Detection & Finalization | TIER 2 - 4 | Complete | 09/03/25 | 11/25/25 | 25.0 | 0.0 |
|
0.0 |
RPL10.SUB.SSB.01300 |
RPL10.SubStructure.SSB - Install UG Utilities - BMS/EPMS/Testing and Pathway Verification and Backfill - Before Impact | Underground | Complete | 09/04/25 | 09/23/25 | 12.5 | 0.0 |
|
0.0 |
RPL10.VDC.3820 |
RPL10.T0 (Center EF to End Corr.) - BIM Review & Approve Shops - Priority 3 | Priority 3 Priority 3 Center EF to End Corridor | Complete | 09/04/25 | 09/04/25 | 1.2 | 0.0 |
|
0.0 |
RPL10.VDC.3880 |
RPL10.T0 (Center EF to End Corr.) - BIM Model/Shops - Priority 3 Final Review (Page Turn) | Priority 3 Priority 3 Center EF to End Corridor | Complete | 09/05/25 | 09/14/25 | 12.5 | 0.0 |
|
0.0 |
PRE.FA.1080 |
Steel - Final Agreement | Trade Partner Final Agreement | Complete | 09/08/25 | 09/08/25 | 0.0 | 0.0 |
|
0.0 |
RPL10.CFCI.4490 |
RPL10 - (SPW - Div 07) Fabricate / Deliver - Below Grade Waterproofing | Waterproofing | Complete | 09/08/25 | 09/19/25 | 8.8 | 0.0 |
|
0.0 |
RPL10.CFCI.4550 |
RPL10 - Submittal Rvw/App'l - Doors, Frames and Hardware | Doors, Frames & Hardware (HM and Wood) | Complete | 09/08/25 | 09/26/25 | 25.0 | 0.0 |
|
0.0 |
RPL10.CFCI.4580 |
RPL10 - Prep / Submit for Review - Joint Sealants | Joint Sealants | Complete | 09/08/25 | 09/16/25 | 8.8 | 0.0 |
|
0.0 |
RPL10.CFCI.4590 |
RPL10- Prep / Submit for Review - Interior Expansion Joints (Spec 07 95 13.13) | Building Expansion Joints (Spec 07 95 13.13) | Complete | 09/08/25 | 09/16/25 | 8.8 | 0.0 |
|
0.0 |
RPL10.VDC.4040 |
RPL10.T0 (mCUP/Exterior) - BIM Prepare & Submit Shops - Priority 1 | Priority 1 mCUP Yard / Exterior | Complete | 09/08/25 | 10/10/25 | 12.5 | 0.0 |
|
0.0 |
RPL10.VDC.4480 |
RPL10.BIM TIER 2 - 4 - Submit Shops | TIER 2 - 4 | Complete | 09/10/25 | 12/01/25 | 31.2 | 0.0 |
|
0.0 |
RPL10.SUB.SSB.01030 |
RPL10.SubStructure.SSB - Foundation For Storm Shelter Rebar CMU | Foundations | Complete | 09/11/25 | 09/12/25 | 3.8 | 0.0 |
|
0.0 |
RPL10.CFCI.3300 |
RPL10 - Prep / Submit for Review - Exterior Louvers (w Ext Metal Panel Trade) (CrownCorr) | Fixed Louvers | Complete | 09/12/25 | 09/22/25 | 25.0 | 0.0 |
|
0.0 |
RPL.10.D.X1015.XR |
Pad Ready (Remaining 25%)- RPL10 (10-09 /10-01) | Pad Ready (XREFs) | Complete | 09/15/25 | 09/15/25 | 0.0 | 0.0 |
|
0.0 |
RPL10.SUB.EF12.01130 |
RPL10.SubStructure.EF12 - Piers Protection Concrete Capping | Foundations | Complete | 09/15/25 | 09/26/25 | 3.8 | 0.0 |
|
0.0 |
RPL10.SUB.NS43.01000 |
RPL10.SubStructure.NS43 - Install Drilled Piers - Grid lines 10-10/10-01 | Foundations | Complete | 09/15/25 | 09/17/25 | 5.0 | 0.0 |
|
0.0 |
RPL10.SUB.NS43.01010 |
RPL10.SubStructure.NS43 - Install Deep/Foundations/Gradebeams/Stemwalls - WBS Summary | Foundations | Complete | 09/15/25 | 11/03/25 | 45.0 | 0.0 |
|
0.0 |
RPL10.SUB.NS43.01020 |
RPL10.SubStructure.NS43 - Install Deep/Foundations/Gradebeams/Stemwalls/UG Utilities - WBS Summary | NS4 & NS3 | Complete | 09/15/25 | 11/19/25 | 60.0 | 0.0 |
|
0.0 |
RPL10.SUB.SSB.01070 |
RPL10.SubStructure.SSB - Install Stem Walls - Grid lines 10-42/10-30 - Before Impact - Part 1 | Foundations | Complete | 09/15/25 | 09/23/25 | 5.0 | 0.0 |
|
0.0 |
RPL.CM.D.C5250.XR |
Logistics Area #5B - OES Equipment Yard Available | Logistics - Area Turnovers XREF Milestones | Complete | 09/16/25 | 09/16/25 | 0.0 | 0.0 |
|
0.0 |
RPL10.CFCI.3840 |
RPL10 - Prep / Submit for Review - Lighting | (CFCI) Div. 26 - Lighting | Complete | 09/16/25 | 09/17/25 | 25.0 | 0.0 |
|
0.0 |
RPL10.CFCI.4840 |
RPL10 - Submittal Rvw/App'l - Joint Sealants | Joint Sealants | Complete | 09/16/25 | 09/19/25 | 25.0 | 0.0 |
|
0.0 |
RPL10.CFCI.4850 |
RPL10 - Submittal Rvw/App'l - Interior Expansion Joints (Spec 07 95 13.13) | Building Expansion Joints (Spec 07 95 13.13) | Complete | 09/16/25 | 09/19/25 | 12.5 | 0.0 |
|
0.0 |
RPL10.CFCI.6840 |
RPL10 - Submittal Rvw/App'l - CRAC Units | (CFCI) Div. 23 - CRAH Units | Complete | 09/16/25 | 10/13/25 | 11.2 | 0.0 |
|
0.0 |
RPL10.CFCI.6900 |
RPL10 - Submittal Rvw/App'l - CRAH Units | (CFCI) Div. 23 - CRAH Units | Complete | 09/16/25 | 10/13/25 | 11.2 | 0.0 |
|
0.0 |
RPL10.SUB.NS12.01030 |
RPL10.SubStructure.NS12 - Install Foundations/Anchor Bolts and Gradebeams - Grid lines 10-30/10-20 - Before Impact)-Pt 1 | Foundations | Complete | 09/16/25 | 09/23/25 | 13.8 | 0.0 |
|
0.0 |
RPL10.VDC.4560 |
RPL10.BIM TIER 2 - 4 - Create Shops | TIER 2 - 4 | Complete | 09/17/25 | 12/01/25 | 18.8 | 0.0 |
|
0.0 |
PRE.FA.1120 |
Fire Supression - Final Agreement | Trade Partner Final Agreement | Complete | 09/18/25 | 09/18/25 | 0.0 | 0.0 |
|
0.0 |
PRE.FA.1160 |
Drywall Metal Studs - Final Agreement | Trade Partner Final Agreement | Complete | 09/18/25 | 09/18/25 | 0.0 | 0.0 |
|
0.0 |
PRE.FA.1180 |
Ceiling - Final Agreement | Trade Partner Final Agreement | Complete | 09/18/25 | 09/18/25 | 0.0 | 0.0 |
|
0.0 |
RPL10.CFCI.4040 |
RPL10 - Submittal Rvw/App'l - Lighting | (CFCI) Div. 26 - Lighting | Complete | 09/18/25 | 11/06/25 | 12.5 | 0.0 |
|
0.0 |
RPL10.CFCI.6560 |
RPL10 - Submittal Rvw/App'l - IWP | Exterior Metal Panels | Complete | 09/18/25 | 10/20/25 | 12.5 | 0.0 |
|
0.0 |
RPL10.CFCI.5130 |
RPL10 - Fabricate / Deliver - Interior Expansion Joints (Spec 07 95 13.13) | Building Expansion Joints (Spec 07 95 13.13) | Complete | 09/22/25 | 11/24/25 | 7.5 | 0.0 |
|
0.0 |
RPL10.SUB.NS43.01130 |
RPL10.SubStructure.NS43 - Piers Protection Concrete Capping (Before Impact) | Foundations | Complete | 09/22/25 | 09/23/25 | 6.2 | 0.0 |
|
0.0 |
RPL10.CFCI.3810 |
RPL10 - Submittal Rvw/App'l - Exterior Louvers (w Ext Metal Panel Trade) | Fixed Louvers | Complete | 09/23/25 | 09/26/25 | 12.5 | 0.0 |
|
0.0 |
NW.1960 |
Weather Event #2 - 09/24/25 - 09/25/25 | Project Impacts | Complete | 09/24/25 | 09/25/25 | 5.0 | 0.0 |
|
0.0 |
RPL10.SUB.SSB.01110 |
RPL10.SubStructure.SSB - Install UG Utilities - BMS/EPMS/Testing and Pathway Verification and Backfill -After Impact | Underground | Complete | 09/25/25 | 10/14/25 | 12.5 | 0.0 |
|
0.0 |
JCL.C.1040 |
RPL10 - Cost Risk LOE-3 Earthwork | Cost LOEs | Active | 09/26/25 | 07/21/26 | 5.0 | 75.0 |
|
72.5 |
JCL.C.1060 |
RPL10 - Cost Risk LOE-4 Rammed Agg Piers | Cost LOEs | Complete | 09/26/25 | 09/26/25 | 5.0 | 0.0 |
|
0.0 |
RPL10.SUB.NS12.01280 |
RPL10.SubStructure.NS12 - Install Foundations/Anchor Bolts and Gradebeams - Grid lines 10-30/10-20 - After Impact)-Pt 2 | Foundations | Complete | 09/26/25 | 10/03/25 | 13.8 | 0.0 |
|
0.0 |
RPL10.SUB.NS12.01300 |
RPL10.SubStructure.NS12 - Install UG Utilities - Building Generator Duct Bank (East)-After Impact - Part 3 | Underground | Complete | 09/26/25 | 10/06/25 | 1.2 | 0.0 |
|
0.0 |
RPL10.SUB.NS43.01230 |
RPL10.SubStructure.NS43 - Piers Protection Concrete Capping (After Impact) | Foundations | Complete | 09/26/25 | 10/13/25 | 6.2 | 0.0 |
|
0.0 |
RPL10.SUB.SSB.01120 |
RPL10.SubStructure.SSB - Scan, Install Backfill and Grading - Grid lines 10-42/10-30 (1st Layer Backfill) | Underground | Complete | 09/26/25 | 10/14/25 | 5.0 | 0.0 |
|
0.0 |
RPL10.SUB.SSB.01240 |
RPL10.SubStructure.SSB - Install UG Utilities - Plumbing/Testing/Backfill-After Impact-Part 2 | Underground | Complete | 09/26/25 | 10/14/25 | 12.5 | 0.0 |
|
0.0 |
RPL10.SUB.SSB.01260 |
RPL10.SubStructure.SSB - Adjust,Scan Install Backfill and Grading - Grid lines 10-42/10-30 (2nd Layer Backfill) | Underground | Complete | 09/26/25 | 10/06/25 | 5.0 | 0.0 |
|
0.0 |
ICM.B10.1830 |
[NWB] Delivery of PTX - Pad Mounted Transformers (First Delivery) | Construction | Complete | 09/29/25 | 09/29/25 | 0.0 | 0.0 |
|
0.0 |
RPL10.CFCI.4120 |
RPL10 - Fabricate / Deliver - Exterior Louvers | Fixed Louvers | Complete | 09/29/25 | 12/11/25 | 6.2 | 0.0 |
|
0.0 |
RPL10.CFCI.4310 |
RPL10 - Fabricate / Deliver - CMU - Storm Shelter | (CFCI) Div. 04 - Concrete Masonry Units | Complete | 09/29/25 | 09/29/25 | 0.0 | 0.0 |
|
0.0 |
RPL10.CFCI.4770 |
RPL10 - Fabricate / Deliver - Doors, Frames and Hardware | Doors, Frames & Hardware (HM and Wood) | Complete | 09/29/25 | 12/19/25 | 0.0 | 0.0 |
|
0.0 |
RPL10.STR.1000 |
RPL10.Structure.BLDG - Erect Steel/Joist/Decking, Remaining UG/SOG - WBS Summary | Structure | Complete | 10/01/25 | 04/10/26 | 160.0 | 0.0 |
|
0.0 |
RPL10.STR.SSB.01000 |
RPL10.Structure.SSB - Install Storm Shelter CMU | Storm Shelter | Complete | 10/01/25 | 10/20/25 | 0.0 | 0.0 |
|
0.0 |
RPL10.STR.SSB.01010 |
RPL10.Structure.SSB - Erect Steel/Joist/Decking, Remaining UG/SOG - WBS Summary | SSB | Complete | 10/01/25 | 03/06/26 | 130.0 | 0.0 |
|
0.0 |
RPL10.SUB.EF12.01030 |
RPL10.SubStructure.EF12 - Install Foundations/Anchor Bolts and Gradebeams - Grid lines 10-20/10-10 | Foundations | Complete | 10/01/25 | 10/13/25 | 13.8 | 0.0 |
|
0.0 |
RPL10.SUB.SSB.01280 |
RPL10.SubStructure.SSB - Install Stem Walls - Grid lines 10-42/10-30 - After Impact - Part 2 | Foundations | Complete | 10/02/25 | 10/02/25 | 0.0 | 0.0 |
|
0.0 |
PRE.FA.1060 |
BMS Controls - Final Agreement | Trade Partner Final Agreement | Complete | 10/03/25 | 10/03/25 | 0.0 | 0.0 |
|
0.0 |
PRE.TPA.1320 |
Non-Critical Trade Buyout - Award and Issue Subcontract | DPR issue Trade Parter Agreements | Complete | 10/06/25 | 11/03/25 | 50.0 | 0.0 |
|
0.0 |
RPL10.CFCI.3370 |
RPL10 - Prep / Submit for Review - Plumbing (OH / In Wall) | (CFCI) Div. 22 - Plumbing | Complete | 10/06/25 | 01/05/26 | 25.0 | 0.0 |
|
0.0 |
RPL10.CFCI.3380 |
RPL10 - Prep / Submit for Review - HVAC Materials and Equipment | (CFCI) Div. 23 - HVAC Materials and Equip. | Complete | 10/06/25 | 10/29/25 | 25.0 | 0.0 |
|
0.0 |
RPL10.SUB.EF12.01070 |
RPL10.SubStructure.EF12 - Install UG Utilities - Plumbing/Testing/Backfill-Part 1 | Underground | Complete | 10/06/25 | 10/14/25 | 8.8 | 0.0 |
|
0.0 |
RPL10.SUB.EF12.01080 |
RPL10.SubStructure.EF12 - Install UG Utilities - WBS Summary | Underground | Complete | 10/06/25 | 11/07/25 | 31.2 | 0.0 |
|
0.0 |